| 2008-11-11 15:43:41 | |
| | |
| | |
| | DENIED |
| | |
| | THE FOLLOWING COMMENTS WERE NOT ADDRESSED FROM 1ST & |
| | 2ND REVIEW |
| | |
| | 3) THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC |
| | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| | PER 108.3 FBC* |
| | |
| | 4) THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON |
| | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER |
| | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE |
| | ADDED TO THE PERMIT APPLICATION FEES |
| | |
| | NOTE: FEES ARE DUE IN THE AMOUNT OF $731.76 FOR |
| | INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS |
| | REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW |
| | |
| | 7) SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 |
| | FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER |
| | AND OWNER/AGENT PRIOR TO SUBMITTAL. NOTE: WHOLE HOUSE |
| | METHOD A WAS CHOSEN PLEASE CORRECT THE AS-BUILT |
| | CALCULATIONS FOR THE GLAZED OPENINGS TO REFLECT ACTUAL |
| | CONDITIONS ON THE DRAWINGS, AMOUNT OF OPENINGS, |
| | ORIENTATION, OVERHANG LENGTH AND HEIGHT, ETC. |
| | ********ADDITION CONTAINS 5 WINDOWS BUT 2 ARE ON THE |
| | NORTH SIDE, 3 ON THE WEST AND 2 ARE ON THE SOUTH, THIS |
| | IS NOT WORST CASE THEREFORE THE SIZES/AREAS SHOULD |
| | MATCH ACTUAL LAYOUT, ALSO THE HEIGHT USED IS FROM THE |
| | SILL TO THE UNDERSIDE OF THE OVERHANG WILL NOT BE THE |
| | SAME ON DIFFERENT WINDOW SIZES THEREFORE THEY CANNOT |
| | ALL BE 1.3 FEET AS STATED********** |
| | |
| | 9) THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF |
| | EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. |
| | *******NO PRODUCT APPROVALS HAVE YET BEEN SUBMITTED FOR |
| | GLASS BLOCK AND LINTELS AND REAR DOOR MIAMI-DADE NOA |
| | HAS EXPIRED. AS THE CITY OF WEST PALM BEACH NO LONGER |
| | REQUIRES THE STATE OF FLORIDA PRODUCT APPROVALS A NEW |
| | UPDATED MIAMI-DADE NOA WOULD BE ACCEPTABLE (SEE NOA |
| | #08-0516.07 AND IT USES THE SAME DRAWING |
| | #S-2004)******** |
| | |
| | 10) THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE |
| | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* |
| | *******ANY NEW PRODUCT APPROVAL SHALL BE REVIEWED AND |
| | APPROVED BY DESIGNER OF RECORD. PLEASE NOTE THAT THE |
| | SHUTTER APPROVALS UNDER THE FLORIDA COVER SHEETS |
| | FL722-R1 ARE NOT VALIDATED BY THE SUBMITTED MIAMI-DADE |
| | NOA, EITHER SUBMIT CORRECT DRAWING FOR THE FLORIDA |
| | APPROVAL OR REMOVE THE FLORIDA COVERS AND SUBMIT THE |
| | NOA BUT THE MIAMI-DADE REPORT WOULD NEED TO BE REVIEWED |
| | AND APPROVED BY THE NEW DESIGNER OF RECORD******** |
| | |
| | 12) PROVIDE A COMPLETED SHUTTER SCHEDULE AND KEY PLAN |
| | FOR THE SHUTTERS (PLEASE SEE ATTACHED CITY MEMO AND |
| | EXAMPLE OF SHUTTER SCHEDULE) |
| | ********THIS IS THE SECOND ATTEMPT WITH MEMO AND |
| | SHUTTER SCHEDULE, THE SCHEDULE MUST ACCOMPANY THE |
| | PRODUCT APPROVAL WITH ALL INFORMATION APPLICABLE FILLED |
| | IN.********** |
| | |
| | 18) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SETS OF PLANS MUST BE STAMPED BY THAT OFFICE, |
| | AND A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE |
| | INFORMATION. |
| | IF THESE FEES HAVE BEEN PAID PLEASE HAVE NO FEE STAMP |
| | ON NEW SETS OF DRAWINGS |
| | |
| | NEW COMMENTS |
| | |
| | 1) CORRECT SITE PLAN SIDE YARD SETBACKS TO MATCH |
| | SURVEY, FOR EXAMPLE SURVEY SHOWS A 6.0' ON SOUTH SIDE |
| | BUT SITE PLAN STATES 9.3'. |
| | *********WAS CHANGED TO INCORRECT SIDE YARD, SEE |
| | SURVEY******** |
| | |
| | REMOVE ALL OLD PAGES, NON USED PRODUCT APPROVALS, ETC. |
| | FROM PACKAGE AND RESUBMIT 2 COMPLETE SETS WITH |
| | REVISIONS AND INCLUDE 1 COPY OF THE OLD PAGES ONLY FOR |
| | REFERENCE. |
| | ********PLEASE REMOVE OLD AND INSERT NEW THIS IS NOT IN |
| | THE SCOPE OF WORK FOR PLAN REVIEWERS, DOCUMENTS SHALL |
| | BE COMPLETE FOR REVIEW AND RECORD RETENTION.******* |
| | |
| | ADDITIONAL PERMITS WILL BE REQUIRED FOR MECHANICAL AND |
| | DRIVEWAY |
| | |
| | BLDG PLAN REVIEW |
| | ADRIAN MORSE |
| | 561-805-6716 |
| | |
| | |