Plan Review Notes
Plan Review Notes For Permit 08060578
Permit Number 08060578
Review Stop B
Sequence Number 1
Notes
Date Text
2008-07-04 09:35:21DENIED
  
 1) PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL
 COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 &
 2007AMENDMENTS PER 106.1.1 FBC*
  
 2) IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING
 MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF
 ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND
 STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE
 DRAWINGS
  
 3) THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 4) THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES
  
  
 NOTE: FEES ARE DUE IN THE AMOUNT OF $731.76 FOR
 INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS
 REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW
  
  
 5) PROVIDE 2 COPIES OF A RECENT SURVEY SHOWING THE
 PROPOSED BUILDING/ADDITION WITH ALL SIDE AND REAR
 SETBACKS, NOTE THAT SURVEY AND SITE PLAN MEASUREMENTS
 DO NOT MATCH
  
 6) PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN
 COMPLIANCE WITH THE REQUIREMENTS OF R403.1 FBC RES.
  
 7) SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER
 AND OWNER/AGENT PRIOR TO SUBMITTAL. NOTE: WHOLE HOUSE
 METHOD A WAS CHOSEN PLEASE CORRECT THE AS-BUILT
 CALCULATIONS FOR THE GLAZED OPENINGS TO REFLECT ACTUAL
 CONDITIONS ON THE DRAWINGS, AMOUNT OF OPENINGS,
 ORIENTATION, OVERHANG LENGTH AND HEIGHT, ETC.
  
 8) PROVIDE AT MINIMUM 1 ACCESSIBLE BATHROOM PER
 R322.1.1 FBC 29" CLEAR WITH DOOR OPEN 90 DEGREES
  
 9) THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF
 EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE
 SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES.
 ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG
  
 10) THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 11) THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL SHEETS WHEN AVAILABLE. THEY CAN
 BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG. WHEN
 AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE
 DENIED
  
 12) NO PRODUCT APPROVALS WERE SUBMITTED FOR ROOF
 SHINGLES, GLASS BLOCK, MULLIONS FOR JOINED WINDOWS,
 FIXED WINDOWS IN FAMILY ROOM, AND LINTELS. PLEASE NOTE
 THAT GLASS BLOCK USING A MORTAR SYSTEM ONLY MEETS SMALL
 MISSILE IMPACT (FL # 1363), THE SILICONE METHOD WILL
 MEET LARGE MISSILE RATING (FL # 5357)
  
 13) IF WOOD BUCKS ARE TO BE USED AN ATTACHMENT DETAIL
 IS REQUIRED FOR THE TRANSFER OF APPLICABLE LOADS TO THE
 BUILDING PER R613.6.1.1 FBC RES.
 SEE DOOR PRODUCT APPROVALS
  
 14) SUBMIT 2 COPIES OF THE SIGNED AND SEALED ENGINEERED
 TRUSS DRAWINGS THAT COMPLY WITH R802.10.1 FBC WITH
 PERMIT APPLICATION OR BEFORE INSTALLATION THAT HAVE
 BEEN REVIEWED AND APPROVED BY THE DESIGNER OF RECORD
  
 15) BUILDING ELEVATION TO INCLUDE MEAN ROOF HEIGHT
  
 16) IN AREAS OF QUESTIONABLE SOILS AS SHOWN IN THE
 OFFICIAL ZONING MAP OF THE CITY OF WEST PALM BEACH, 2
 ORIGINAL COPIES OF A SOIL TEST REPORT SHALL BE
 SUBMITTED PER R401.4 FBC RES.
  
 17) PROVIDE ATTIC ACCESS ON DRAWINGS TO ALL AREAS AS
 REQUIRED PER R807.1 FBC RES.
  
 18) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SETS OF PLANS MUST BE STAMPED BY THAT OFFICE,
 AND A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE
 INFORMATION.
 IF THESE FEES HAVE BEEN PAID PLEASE HAVE NO FEE STAMP
 ON NEW SETS OF DRAWINGS
  
 19) PER 713.13(2) F.S. IF THE IMPROVEMENT DESCRIBED IN
 THE NOC HAS NOT COMMENCED WITHIN 90 DAYS OF RECORDING,
 THE NOTICE IS VOID. PLEASE NOTE THAT NO IMPROVEMENT WAS
 GIVEN IN THE OLD NOC THIS AREA MUST BE FILLED OUT IN
 THE NEW ONE. IN ORDER TO AVOID THE 90 DAY RULE NOC CAN
 BE RECORDED ONCE THE PERMIT HAS BEEN ISSUED.
  
 20) PRODUCT APPROVALS WERE SUBMITTED FOR FLAT ROOF
 PRODUCT BUT NO FLAT ROOF ON THE PLANS, ALSO FOR AN
 INSWING FIBERGLASS DOOR WITH SIDELITES THAT IS NOT
 PRESENT ON DRAWINGS, PLEASE CLARIFY
  
 21) PLEASE CLARIFY NEW WORK TO FRONT FACADE OF HOUSE,
 SHEET A2, SOUTH ELEVATION SHOWS NEW ENTRY AND A1 STATES
 EXISTING IS THE NEW SCOPE OF WORK FOR THE FRONT ONLY
 NEW WINDOWS?
  
 22) REMOVE ALL OLD PAGES, NON USED PRODUCT APPROVALS,
 ETC. FROM PACKAGE AND RESUBMIT 2 COMPLETE SETS WITH
 REVISIONS AND INCLUDE 1 COPY OF THE OLD PAGES ONLY FOR
 REFERENCE.
  
 23) ADDITIONAL PERMITS WILL BE REQUIRED FOR MECHANICAL
 AND DRIVEWAY
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716