| Date |
Text |
| 2008-08-06 15:37:33 | RESIDENTIAL (R3) ADDITION, BUILDING REVIEW SECOND |
| | CHECKLIST. |
| | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. |
| | |
| | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH |
| | COUNTY TO VERIFY IF IMPACT FEES ARE DUE. BRING BACK |
| | STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. |
| | (REPEAT COMMENT). |
| | |
| | 2- CLARIFY IF BEDROOM WINDOWS WILL BE CUSTOM MADE |
| | WINDOWS. THERE ARE NOT STANDARD 4'X5' WINDOWS. SEE |
| | PRODUCT APPROVAL FOR STANDARD WINDOW SIZES. PROVIDE |
| | MANUFACTURER'S CUT SHEETS FOR WINDOWS OTHER THAN THE |
| | STANDARD EGRESS WINDOWS TO VERIFY COMPLIANCE WITH SEC. |
| | R310.1.2. (REPEAT COMMENT). |
| | |
| | 3- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY |
| | DCA RULE 9B-72 FOR: |
| | A) SWING DOOR AT NEW CLOSET AREA. (REPEAT COMMENT). |
| | |
| | B) SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS AND |
| | DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL |
| | COVER PAGE AND PAGE WHERE CONNECTOR IS SHOWN TO SAVE |
| | TIME AND PAPER. (REPEAT COMMENT). |
| | |
| | 4- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. |
| | NOTE: |
| | |
| | 5- SHEET 2 OF 2: REVISE ROOF SHEATHING NAIL SPACING FOR |
| | ZONE #3. SEE SEC. R803.2.3.1 FOR REQUIRED NAIL SPACING |
| | AT ROOF ZONE #3 AND REVISE ROOF SHEATHING NAILING |
| | SCHEDULE AS REQUIRED. (REPEAT COMMENT). |
| | NOTE: NAIL SPACING AT INTERMEDIATE SUPPORTS IS MISSING. |
| | ONLY NAILING AT EDGES WAS SPECIFIED. REVISE AS |
| | REQUIRED. |
| | |
| | 6- TRUSS PACKAGE: |
| | A) REVISE TRUSS LOAD CRITERIA TO MATCH LOAD CRITERIA |
| | SPECIFIED BY THE ENGINEER OF RECORD ON SHEET 1 OF 2.. |
| | INFORMATION SUBMITTED DON'T MATCH. |
| | |
| | B) ENGINEER OF RECORD TO REVIEW AND APPROVE TRUSS |
| | PACKAGE PRIOR TO SUBMITTAL TO THIS OFFICE. |
| | |
| | C) PROVIDE COMPLETE TRUSS PACKAGE. ONLY THE TRUSS |
| | LAYOUT WAS SUBMITTED THIS TIME. |
| | |
| | 7- SURVEY NEEDS TO HAVE SURVEYOR'S ORIGINAL SIGNATURE |
| | (NOT COPY) AS REQUIRED BY SEC. 61G17-7.0025 OF FLORIDA |
| | ADMINISTRATIVE CODE AND SEC. 472 FLORIDA STATUTE. |
| | |
| | ***NOTE: TO EXPEDITE REVIEW PROCESS, PLEASE DON'T |
| | STAPLE TOGETHER OLD DRAWINGS WITH NEW DRAWINGS. |
| | |
| | JULIO GOMEZ |
| | BUILDING PLANS EXAMINER |
| | (561)805-6712 |