| 2008-06-19 11:30:11 | 6-19-08 |
| | BUILDING PLAN REVIEW |
| | PERMIT: 08060201 |
| | ADD: 3700 GEORGIA AVE #10 |
| | CONT: PRINCIPLE CONSTRUCTION LLC |
| | TEL: (561) 533-5252 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW: 1ST |
| | ACTION: DENIED |
| | |
| | 1)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE |
| | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | 2)PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) |
| | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC |
| | BUILDING WITH THE 2007 SUPPLEMENTS. |
| | |
| | 3)ADDITIONAL INFORMATION REQUIRED 106.1.2* SUBMIT AN |
| | EXISTING FLOOR PLAN AND A PROPOSED FLOOR PLAN SHOWING |
| | ALL CHANGES TO THE EXISTING LAYOUT. THE ADDRESS ON THE |
| | PLANS SHALL INCLUDE THE UNIT/SUITE NUMBER FOR |
| | INSPECTION PURPOSES. |
| | |
| | 4)TABLE 803.5 MINIMUM INTERIOR FINISH CLASSIFICATION; |
| | PROVIDE INFORMATION BASED ON INTERIOR FINISH |
| | REQUIREMENTS BASED ON OCCUPANCY. |
| | |
| | 5)THE DOOR IN THE CORRIDOR SHALL A MINIMUM FIRE |
| | PROTECTION RATING OF 20 MINUTES, SO PLEASE INDICATE THE |
| | RATING IN MINUTES PER TABLE 715.3 SEE SECTION 715.3.3 |
| | FOR MORE INFORMATION. |
| | |
| | 6)INDICATE ON THE PLANS THE OCCUPANT LOAD OF THE |
| | SPACE PER SECTION 1004 AND TABLE 1004.1.2. STATE THE |
| | USE OF THE OPEN AREA. PROVIDE A WALL LEGEND SHOWING THE |
| | EXISTING WALLS AND THE NEW CONSTRUCTED WALLS. DEPENDING |
| | ON THE USE OF OPEN SPACE ADDITIONAL COMMENTS MAY APPEAR |
| | ON THE NEXT REVIEW. |
| | |
| | 7)OFFICE #3 HAS NO ACCESS TO THE SPACE EXCEPT GOING |
| | THROUGH THE CORRIDOR. IF THIS IS A SEPARATE TENANT, THE |
| | SEVEN FOOT INTERIOR WALLS AROUND THIS SPACE WILL HAVE |
| | TO BE CHANGED TO PROVIDE TENANT SEPARATION FBC708.1 |
| | |
| | 8)108.3* THE CLAIMED VALUATION ON THE PERMIT |
| | APPLICATION IS LOW. FOR PERMITTING PURPOSES VALUATION |
| | OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT |
| | STRUCTURAL, ELECTRIC INTERIOR FINISHES, ARCHITECTURAL |
| | DESIGN FEES, MARKETING COSTS OVERHEAD AND PROFIT |
| | EXCLUDING LAND. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | [email protected] |