| Plan Review Notes For Permit 08060149 |
| Permit Number |
08060149 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2008-06-10 08:50:22 | DURING PRE-INSPECT WAS ABLE TO GET ON ROOF. NOTICED | | | SEVERE CRACKING TO CAP SHEET, SPONGY UNDER FOOT | | | INDICATING WATER IN PLYS. CALLED CONTRACTOR, AND WE | | | AGREED THIS SHOULD BE A RE-ROOF COMPLETE TEAR OFF. HE | | | WILL REVISE SCOPE OF WORK. |
|