| Date |
Text |
| 2008-06-06 09:37:42 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| | CODE |
| | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* |
| | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 |
| | |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FSFLORIDA STATUTE |
| | |
| | |
| | 1.PLEASE SHOW ALL EXIT DOORS ON THE PLAN, FBC CHAPTER |
| | 10. |
| | |
| | 2.STEEL SUBSTRATE IS NOT INCLUDED IN THE ACCORDION |
| | PRODUCT APPROVAL.AS YOU ARE USING THE PRODUCT IN A |
| | MANNER OTHER THAN PERMITTED WITHIN THE PRODUCT APPROVAL |
| | REPORT, ENGINEERING IS REQUIRED (ANCHORS INTO A STEEL |
| | SUBSTRATE). |
| | |
| | 3.SEE ATTACHED IMPLEMENTATION STANDARD, ITEM 13.USE |
| | OF REMOVABLE IMPACT PROTECTION ON COMMERCIAL BUILDINGS |
| | REQUIRES APPROVAL BY THE BUILDING OFFICIAL.PLEASE |
| | PROVIDE A PRE-STORM PREPARATION PLAN WITH ALL |
| | INFORMATION REQUIRED.A PRELIMINARY REVIEW MAY BE DONE |
| | BY EMAIL PRIOR TO RESUBMITTAL.THE CONTRACTOR IS |
| | ENCOURAGED TO HAVE THE PRE STORM PREPARATION PLAN |
| | APPROVED PRIOR TO RESUBMITTAL. |
| | |
| | 4.THE DETAIL CIRCLED ON THE ARMOR SCREEN PRODUCT |
| | APPROVAL IS FOR ATTACHMENT INTO A CONCRETE FOOTER. THIS |
| | IS A SECOND STORY APPLICATION.IF DETAILS ARE CIRCLED |
| | ON THE PRODUCT APPROVAL, THEY SHOULD CORRELATE WITH THE |
| | SPECIFIC JOB.CIRCLING OF DETAILS IS NOT REQUIRED FOR |
| | PERMIT ISSUANCE AS ALL REQUIRED INFORMATION SHOULD BE |
| | INCLUDED ON THE INSTALLATION SCHEDULE. |
| | |
| | 5.PLEASE ADVISE THE OWNER THAT THE PRODUCT SUBMITTED, |
| | ARMOR SCREEN, WITH A SHUTTER TO GLASS SEPARATION OF 0, |
| | WILL NOT PREVENT THE GLASS FROM BREAKING, POSSIBLY |
| | RESULTING IN BROKEN WINDOWS DURING A STORM EVENT (AND |
| | WATER INTRUSION AS A RESULT).NOTE THAT THIS COMMENT |
| | IS MADE AT THIS TIME AS ADVISORY ONLY AS THE OWNER IN |
| | THIS CASE IS THE CITY OF WEST PALM BEACH.ONCE ADVISED |
| | AND IF THE PRODUCT IS ACCEPTED, THIS COMMENT WILL NOT |
| | PREVENT THE PERMIT FROM BEING ISSUED. |
| | |