| Date |
Text |
| 2008-06-25 16:20:49 | |
| | |
| | DENIED |
| | |
| | 1)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC |
| | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| | PER 108.3 FBC* |
| | |
| | 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON |
| | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER |
| | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE |
| | ADDED TO THE PERMIT APPLICATION FEES |
| | |
| | |
| | NOTE: FEES ARE DUE IN THE AMOUNT OF $31.66FOR |
| | INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS |
| | REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW |
| | |
| | 3)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE |
| | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* |
| | |
| | 4) SUBMIT ENGINEERED TRUSS DRAWINGS THAT COMPLY WITH |
| | R802.10.1 FBC WITH PERMIT APPLICATION OR BEFORE |
| | INSTALLATION THAT HAVE BEEN REVIEWED AND APPROVED BY |
| | THE DESIGNER OF RECORD |
| | |
| | 5)THE 2006 AMENDMENTS TO THE 2004 FBC (1609.4) |
| | REQUIRE BUILDINGS LOCATED WITHIN EXP B TYPE TERRAIN |
| | THAT IS DIRECTLY ADJACENT TO EXP C TYPE TERRAIN SUCH AS |
| | OPEN GOLF COURSES AND BODIES OF WATER FOR A DISTANCE OF |
| | 600 FEET OR MORE IN ANY QUADRANT TO BE IN AN EXP C |
| | CATEGORY. PLEASE ADJUST THE DESIGN PARAMETERS AND WIND |
| | PRESSURES ACCORDINGLY. NOTE: THE PRODUCT APPROVAL |
| | DESIGN PRESSURES SEEM TO WORK EVEN AT THE INCREASED |
| | VALUES |
| | |
| | 6)PROVIDE DETAILS OF THE STRUCTURAL BUILDING |
| | CONNECTION WHERE NEW AND EXISTING FOUNDATIONS, COLUMNS |
| | AND TIE BEAMS ARE JOINED |
| | |
| | 7)PROVIDE TOP OF BEAM AND MEAN ROOF HEIGHT |
| | ELEVATIONS |
| | |
| | 8)SUBMIT A COPY OF THE RECORDED NOTICE OF |
| | COMMENCEMENT TO THE CONSTRUCTION SERVICES DEPARTMENT. |
| | |
| | REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS WITH |
| | REVISIONS AND INCLUDE 1 COPY OF THE OLD PAGES ONLY FOR |
| | REFERENCE. |
| | |
| | ADDITIONAL PERMITS WILL BE REQUIRED FORELECTRICAL |
| | AND ROOFING |
| | |
| | BLDG PLAN REVIEW |
| | ADRIAN MORSE |
| | 561-805-6716 |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |