Plan Review Notes
Plan Review Notes For Permit 08050714
Permit Number 08050714
Review Stop B
Sequence Number 2
Notes
Date Text
2008-06-03 13:32:40RESIDENTIAL (R3) ROOF RECOVERING, BUILDING REVIEW
 CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2007 REVISIONS.
  
 ***NOTE: PERMIT IS ON HOLD UNTIL FOLLOWING ISSUES ARE
 CLARIFIED.PLEASE DO NOT DO ANY WORK UNTILL PERMIT IS
 RE-ACTIVATED TO AVOID ANYCONFLICTS.
  
 1- PROVIDEPRODUCT APPROVAL FOR RECOVERING APPLICATION
 AS STATED ON PERMIT APPLICATION AS REQUIRED BY DCA RULE
 9B -72.NOA 07-0604.04 SUBMITTED IS FOR NEW
 CONSTRUCTION OR REROOF APPLICATION.SELECTED ASSEMBLY
 ON PAGE 7 OF NOA SUBMITTED IS FOR A WOOD NON-INSULATED
 DECK.CONTRACTOR IS SUBMITTING INSULATION
 INFORMATION.ANY MODIFICATIONS TO THE NOA VOID THE
 PRODUCT APPROVAL. SEE NOTE #3 ON GENERAL LIMITATIONS
 NOTES ON SHEET 15 OF NOA SUBMITTED.
  
 2- ACCORDING TO SEC. 511.4 OF 2004 FLORIDA EXISTING
 BUILDING CODEROOF RECOVERING OVER WOOD SHAKES
 REQUIRES THE ENTIRE EXISTING SURFACE TO BE COVERED WITH
 GYPSUM BOARD, MINERAL FIBER,GLASS FIBER OR OTHER
 APPROVED MATERIALS SECURELYFASTENED IN PLACE.RBI
 SHIELD IS A REFLECTIVE INSULATION AND NEEDS APPROVAL
 FROM BUILDING OFFICIAL.
  
 3- HOUSE IS LOCATED IN WIND EXPOSURE "C". SEE SEC.
 R301.2.1.4(3) OF 2004 FLORIDA RESIDENTIAL CODE. UPLIFT
 PRESSURES NEED TO BE TAKEN INTO CONSIDERATION FOR
 PROPOSED INSTALLATION.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712


Account Summary | Usage Policy | Privacy Policy