| Plan Review Notes For Permit 08050714 |
| Permit Number |
08050714 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2008-06-03 13:32:40 | RESIDENTIAL (R3) ROOF RECOVERING, BUILDING REVIEW | | | CHECKLIST. | | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | | | ***NOTE: PERMIT IS ON HOLD UNTIL FOLLOWING ISSUES ARE | | | CLARIFIED.PLEASE DO NOT DO ANY WORK UNTILL PERMIT IS | | | RE-ACTIVATED TO AVOID ANYCONFLICTS. | | | | | | 1- PROVIDEPRODUCT APPROVAL FOR RECOVERING APPLICATION | | | AS STATED ON PERMIT APPLICATION AS REQUIRED BY DCA RULE | | | 9B -72.NOA 07-0604.04 SUBMITTED IS FOR NEW | | | CONSTRUCTION OR REROOF APPLICATION.SELECTED ASSEMBLY | | | ON PAGE 7 OF NOA SUBMITTED IS FOR A WOOD NON-INSULATED | | | DECK.CONTRACTOR IS SUBMITTING INSULATION | | | INFORMATION.ANY MODIFICATIONS TO THE NOA VOID THE | | | PRODUCT APPROVAL. SEE NOTE #3 ON GENERAL LIMITATIONS | | | NOTES ON SHEET 15 OF NOA SUBMITTED. | | | | | | 2- ACCORDING TO SEC. 511.4 OF 2004 FLORIDA EXISTING | | | BUILDING CODEROOF RECOVERING OVER WOOD SHAKES | | | REQUIRES THE ENTIRE EXISTING SURFACE TO BE COVERED WITH | | | GYPSUM BOARD, MINERAL FIBER,GLASS FIBER OR OTHER | | | APPROVED MATERIALS SECURELYFASTENED IN PLACE.RBI | | | SHIELD IS A REFLECTIVE INSULATION AND NEEDS APPROVAL | | | FROM BUILDING OFFICIAL. | | | | | | 3- HOUSE IS LOCATED IN WIND EXPOSURE "C". SEE SEC. | | | R301.2.1.4(3) OF 2004 FLORIDA RESIDENTIAL CODE. UPLIFT | | | PRESSURES NEED TO BE TAKEN INTO CONSIDERATION FOR | | | PROPOSED INSTALLATION. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|