| 2008-10-27 13:22:25 | ****CORRECTIONS**** |
| | ***REVISION*** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2004 |
| | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| | CODE |
| | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FS FLORIDA STATUTE |
| | |
| | FROM PREVIOUS REVIEWS: |
| | |
| | 1. DECLARE GOVERNING CODE, INCLUDING 2007 |
| | REVISIONS/SUPPLEMENTS. |
| | |
| | 2. DECLARE LEVEL OF ALTERATION, FBC EB CHAPTER 3. |
| | |
| | 3. INCLUDE A CODE SUMMARY; BUILDING TYPE FBC6, BUILDING |
| | HEIGHT AND AREA FBC5, SPRINKLER INFORMATION, OCCUPANCY |
| | CLASSIFICATION FBC 3 AND AREA PER OCCUPANCY. INCLUDE |
| | EXISTING OCCUPANCY CLASSIFICATION AS WELL AS PROPOSED |
| | OCCUPANCY CLASSIFICATION. |
| | |
| | 4. THE PLAN SHOWS REMOVAL OF WALL AND ROOF PANELS. A |
| | DEMO PERMIT CANNOT BE ISSUED AS THIS AFFECTS THE |
| | STRUCTURAL INTEGRITY OF THE BUILDING, FBC EB 501.2. |
| | |
| | 5. THIS PERMIT WAS FOR INTERIOR DEMO. OTHER PERMITS ARE |
| | OPEN AND PENDING ON THIS BUILDING. PROVIDE A SITE PLAN |
| | SHOWING THE LOCATION OF THE BUILDING, AS WELL AS |
| | LOCATION OF THE TWO SPACES AND SCOPE OF WORK UNDER THE |
| | DIFFERENT PERMITS. IT APPEARS THAT THIS WORK SHOULD BE |
| | UNDER PERMIT 08090571, EXTERIOR REPAIRS. |
| | |
| | 6. PROVIDE A VALUE FOR THE ADDITIONAL WORK. |
| | |
| | 7. COMPLIANCE WITH REQUIREMENTS FOR EXITING FBC CHAPTER |
| | 10, ENERGY FBC CHAPTER 13, ACCESSIBILITY FBC CHAPTER |
| | 11, AND THRESHOLD BUILDING REQUIREMENTS CANNOT BE |
| | DETERMINED. PROVIDE COMPLETE PLANS FOR ALL |
| | IMPROVEMENTS, FBC*106. |
| | |
| | NEW COMMENTS: |
| | |
| | 8. DUE TO OCCUPANT LOAD, THIS IS A THRESHOLD BUILDING |
| | FS553.71. THRESHOLD INSPECTOR REQUIRED. PEASE ARRANGE |
| | WITH KEN CONRAD (CHIEF BUILDING INSPECTOR, 561 805 |
| | 6666), A MEETING INVOLVING THE OWNER, SPECIAL |
| | INSPECTOR, JOB INSPECTOR, CONTRACTOR AND ENGINEER. THIS |
| | MUST BE DONE PRIOR TO PERMIT ISSUANCE. THREE ORIGINAL |
| | SETS OF ALL DOCUMENTS ARE REQUIRED FOR PERMITTING AND |
| | FOR ALL SUBSEQUENT SUBMITTALS. SEE FBC*109.3.6. THIS |
| | MUST BE DONE IMMEDIATELY OR A STOP WORK ORDER WILL BE |
| | ISSUED. |
| | |
| | 9. PROVIDE A STRUCTURAL INSPECTION PLAN, FBC*109.3.6 |
| | FOR THIS THRESHOLD BUILDING. |
| | |
| | 10. SEE FBC*109.3.6.4.4 AND FS553.71 AND INCLUDE THE |
| | STATEMENT ATTESTING TO COMPLIANCE. |
| | |
| | |
| | |
| | |