| Plan Review Notes For Permit 08050615 |
| Permit Number |
08050615 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2008-06-20 10:57:02 | ****************PROVISO**************** | | | A} FBC-2004 SEC. 424.2.9, OR FBCR-2004 SEC. | | | R4101.9 WATER SUPPLY, LOCAL ORD. | | | #2853-95, BACKFLOW REQUIRED ON WATER | | | SERVICE. | | | | | | B} FBC-2004 SEC. 424.2.12.1, OR | | | FBCR-2004 SEC. R4101.12.1 PRESSURE | | | TESTS. PER MANUFACTURE RECOMMENDATIONS, | | | NO AIR TEST SHALL BE APPROVED FOR PVC | | | PIPE AND FITTINGS. | | | | | | C} FBC-2004 SEC. 424.2.14.4, OR | | | FBCR-2004 SEC. R4101.14.4 CONNECTIONS, | | | ALL WATER HEATING EQUIPMENT SHALL BE | | | INSTALLED WITH FLANGES OR UNION | | | CONNECTIONS ADJACENT TO THE HEATER. | | | | | | D} FBC-2004 SEC. 424.2.13.2, OR | | | FBCR-2004 SEC.R4101.13.2 JOINTS AND | | | CONNECTIONS, FBC PLMG SEC 605.21, PURPLE | | | PRIMER REQUIRED ON PVC PIPING. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|