Plan Review Notes
Plan Review Notes For Permit 08050594
Permit Number 08050594
Review Stop P
Sequence Number 1
Notes
Date Text
2008-06-09 09:33:31DENIED
 REFERENCE: FB2004 PLUMBING
 FBC-2004 CHAPTER 1
 CITY WPB MINICIPAL CODE
  
 1. SHT 1 OF 4 INDICATES 3" WASTE LINE TO STORM SEWER.
 WASTE FROM THE FILTER SYSTEM SHALL CONNECT TO THE
 SANITARY SYSTEM. ARTICLE III SECTION 90-203.
  
 2. SHT 3 OF 4 INDICATES 2 HEAT PUMPS. SUBMIT MANUF.
 SPECIFICATION SHEETS FOR THE HEAT PUMPS. SPECIFICATION
 SHEETS SHALL SHOW LISTING FOR PRODUCT. SECTION 303.4.
  
 3. SHT 4 OF 4 LEGEND "D" INDICATES 3" WASTE LINE TO
 STORM SEWER.WASTE FROM THE FILTER SYSTEM SHALL
 CONNECT TO THE SANITARY SYSTEM. ARTICLE III SECTION
 90-203.
  
 4. SHT 4 OF 4 LEGEND "J" INDICATES OVERFLOW TO
 DISCHARGE TO GROUND.PER SECTION 1101.2 THE OVERFLOW
 FROM THE STORM WATER SHALL CONNECT TO THE STORM
 SYSTEM.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  