| Plan Review Notes For Permit 08050554 |
| Permit Number |
08050554 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2008-05-21 10:45:48 | RESIDENTIAL(R3)SHUTTERS,BUILDINGREVIEW | | | CHECKLIST. | | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | | | 1- REVISE INSTALLATION SCHEDULE ANCHOR SPACING.ANCHOR | | | SPACING ON SHUTTERS PRODUCT APPROVAL PAGE 10 OF 14IS | | | TO BE USED ONLY WHEN THE EDGE DISTANCE IS 3-1/2". | | | INFORMATION GIVEN ON CITY'S INSTALLATION SCHEDULE SHOWS | | | THE EDGE DISTANCE TO BE AT 3".ACCORDING TO PAGE 11 OF | | | 14 OFSHUTTERS DRAWINGS ANCHOR SPACING NEEDSTO BE | | | REDUCED AS REQUIRED BY THE EDGE DISTANCE VERSUS SPACING | | | FOR ANCHORS TABLE.REVISE ANCHOR SPACING IN CITY'S | | | INSTALLATION SCHEDULE AS REQUIRED. | | | | | | 2-NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY | | | SEC. 713.13 FLORIDA STATUTE. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|