| Date |
Text |
| 2008-05-30 09:58:58 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| | CODE |
| | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* |
| | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 |
| | |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FSFLORIDA STATUTE |
| | |
| | 1.ON THE EXISING HOUSE PLAN, SHOW ROOM DESIGNATIONS. |
| | IT IS NOT CLEAR WHETHER OR NOT BEDROOM EGRESS HAS BEEN |
| | AFFECTED. |
| | |
| | 2.PROVIDE A SITE PLAN WHICH DOES NOT HAVE OLD CITY |
| | PERMIT STAMPS ON IT. |
| | |
| | 3.FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED |
| | FOR THE ROOF PANELS, FAC9B72. |
| | |
| | 4. PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER OF |
| | RECORD (SHOP DRAWING REVIEW STAMP OR LETTER), |
| | FBC*106.3.3. |
| | |
| | 5.ADDITIONAL FEES DUE (RADON).PLEASE PAY PRIOR TO |
| | RESUBMITTAL. |
| | |
| | 6.PROVIDE A CURRENT SURVEY WHICH SHOWS THE PROPERTY |
| | LINES.THE SURVEY SUBMITTED IS DIFFICULT TO READ AND |
| | THE PROPERTY LINE IS NOT CLEARLY INDICATED.THIS |
| | APPEARS TO BE A PROPOSED SURVEY.(THE SURVEY SUBMITTED |
| | SHOWS FOUR UNITS ON ONE PARCEL; IT DOES NOT DESIGNATE |
| | THE UNITS' LOT LINES.) |
| | |
| | IN LIEU OF PROVIDING A CURRENT SURVEY, THE AERIAL |
| | AVAILABLE ON PAPA MAY BE PROVIDED.THE PLANS ARE TO |
| | CLEARLY SHOW THAT THE PROPOSED IMPROVEMENT WILL BE |
| | BUILT ENTIRELY WITHIN THIS LOT. |
| | |