Date Text
2008-07-01 13:52:19****CORRECTIONS****
 REVISION, NEW ROOF PANEL NOA
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.PRODUCT APPROVALS ARE TO BE REVIEWED BY DESIGNER OF
 RECORD, FBC*106.3.3.
  
 2.THE NOA PREVIOUSLY SUBMITTED HAD A DESIGN PRESSURE
 LIMITATION OF -91.87, -113.1 FOR FIELD,
 PERIMETER/CORNER.THE NEW NOA HAS A LIMITATION OF
 -50.5, -106.15.THE ENGINEER DID NOT INCLUDE WIND
 DESIGN CRITERIA ON HIS PLAN.IF THE ENGINEER IS NOW
 REDUCING DESIGN PRESSURE REQUIREMENTS, PLEASE INCLUDE
 ROOF DESIGN PRESSURES EITHER WITH A LETTER OR PLAN
 SHEET REVISION.
  
 3.FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED IN
 ADDITION TO THE NOA SUBMITTED.IF A FLORIDA STATE
 PRODUCT APPROVAL IS NOT AVAILABLE, PLEASE ADVISE AND A
 LOCAL PRODUCT APPROVAL WILL BE ISSUED.
  