Plan Review Notes
Plan Review Notes For Permit 08050357
Permit Number 08050357
Review Stop P
Sequence Number 1
Notes
Date Text
2008-06-02 09:39:29DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 11
  
 1. SHT A3.0, DETAIL 10. SHOW COMPLIANCE WITH THE
 FOLLOWING FOR THE SINK.
 A. 11-4.24.3 KNEE CLEARANCE
 B. 11-4.24.4 SINK DEPTH
 C. 11-4.24.5 CLEAR FLOOR SPACE
 D. 11-4.24.6 EXPOSED PIPES & SURFACES
 E. 11-4.24.7 FAUCETS
  
 2. SHT P0.1 THE WATER RISER DIAGRAM DOES NOT RELFECT
 THE FLOOR PLAN. SEE SHT A3.0 DETAIL 10 AS IT SHOWS A
 REFRIGERATOR ON THE RIGHT SIDE OF THE SINK AND AN ICE
 MAKER ON THE LEFT SIDE OF THE SINK. PLEASE SHOW BOTH ON
 THE RISER DIAGRAM. ALSO THE RISER IS SHOWING THE COLD
 SUPPLY ON THE LEFT SIDE OF THE SINK AND THE HOT SUPPLY
 ON THE RIGHT SIDE OF THE SINK. SECTIONS 106.1.1 &
 607.4.--THE HOT WATER TO THE DISHWASHER REQUIRES A
 WATER HAMMER ARRESTOR PER SECTION 604.9.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]