| 2008-05-05 15:47:03 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.DESIGN PRESSURES ARE TOO LOW, PLEASE SEE FBC | | | R301.2.(2).PLEASE REVISE INSTALLATION SCHEDULE. | | | | | | 2.A 2 1/2" EDGE DISTANCE REQUIRES USING A FACTOR OF | | | .75 FOR ANCHOR SPACING, SEE SHEET 8 OF THE PRODUCT | | | APPROVAL.9" SPACING IS SPECIFIED ON THE INSTALLATION | | | SCHEDULE; THIS IS FOR 3" EDGE DISTANCE.PLEASE | | | REVISE. | | | |
|