| Date |
Text |
| 2008-05-12 14:40:46 | 2004 FBC W/2007 REVISIONS |
| | ADDITION |
| | |
| | DENIED BY BUILDING |
| | |
| | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT |
| | MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 2) BEFORE A PERMIT TO CONSTRUCT CAN BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY.THE PLANS MUST BE |
| | STAMPED AND THE RECEIPT ATTACHED TO THE APPLICATION. |
| | 233-5025 |
| | |
| | 3) SUBMIT ENERGY CALCULATIONS AS REQUIRED BY 2004 FBC |
| | CHAPTER 13. |
| | |
| | 4) SPECIFY THE MAXIMUM SPACING ALLOWED FOR THE #5 |
| | VERTICAL REINFORCEMENT IN THE NEW EXTERIOR WALLS. FBC |
| | R609.3.3 |
| | |
| | 5) ROOF SHEATHING IS REQUIRED TO BE IN ACCORDANCE WITH |
| | SECTION R803.2.3.1 OF 2006 REVISIONS TO 2004 FBC |
| | RESIDENTIAL CODE. WOOD STRUCTURAL PANEL SHEATHING SHALL |
| | BE FASTENED TO ROOF FRAMING WITH 8D RING-SHANK NAILS. |
| | PLEASE MAKE CORRECTIONS ON SHEET 5. |
| | |
| | 6) SPECIFY THE COMPONENT AND CLADDING UPLIFT PRESSURES |
| | FOR THE FLAT ROOF ZONES 1,2 AND 3. SEE FBC TABLE |
| | R301.2(2) AND FIGURE R301.2(8). |
| | |
| | 7)FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE |
| | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | PLEASE USE A SHOP DRAWING REVIEW STAMP FROM THE |
| | ENGINEER, AS THE SIGNATURES ON THE PRODUCT APPROVALS DO |
| | NOT APPEAR TO BE THE ENGINEER'S. |
| | |
| | 8)SPECIFY WHICH ONE OF THE APPROVED ASSEMBLIES LISTED |
| | IN THE NOA FOR THE MODIFIED ROOFING WILL BE INSTALLED. |
| | SPECIFY THE FASTENING OPTION OPTION THAT WILL BE USED |
| | AND THE DESIGN PRESSURE. IF ENHANCED FASTENING IS |
| | REQUIRED FOR THE PERIMETER AND CORNER AREAS, SUBMIT RAS |
| | 117 CALCULATIONS. |
| | |
| | 9) THE NOA FOR THE TRACO SERIES 2100 HAS BEEN |
| | SUPERSEDED BY NOA NO. 07-0521.06. SUBMIT THE NEW NOA. |
| | |
| | 10) THE ELEVATION ON SHEET 3 OF THE PLANS SPECIFIES A |
| | GLAZED FRENCH DOOR WHICH WILL REQUIRE STORM PANELS IF |
| | IT IS NOT AN IMPACT RATED DOOR. THE PRODUCT APPROVAL |
| | THAT WAS SUBMITTED IS FOR AN OPAQUE STEEL DOOR. PLEASE |
| | CLARIFY. |
| | |
| | 11) SUBMIT PRODUCT APPROVALS FOR THE STORM PANELS AS |
| | REQUIRED BY FBC R301.2.1.2 AND DCA RULE 9B-72. SUBMIT 2 |
| | COPIES OF A KEY PLAN AND INSTALLATION SCHEDULE FOR THE |
| | STORM PANELS. SPECIFY THE OPENING SIZES, PANEL SPANS, |
| | FASTENER TYPE AND SPACING, CONNECTION TYPE, PRESSURES, |
| | ETC. SEE ATTACHED. |
| | |
| | 12) PLEASE DO NOT STAPLE THE PRODUCT APPROVALS TO THE |
| | PLANS. |
| | |
| | 13) THE DECLARED VALUE OF THE WORK IS TOO LOW. IT HAS |
| | BEEN ADJUSTED TO $ 65,154.00. THERE ARE ADDITIONAL |
| | PERMIT FEES DUE OF $199.62. FBC 108.3* CITY AMENDMENTS |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |
| | |