| 2008-09-22 14:38:19 | ***LANDSCAPE REVIEW FAILED*** |
| | |
| | 1. THE LANDSCAPE PLAN SHALL BE DRAWN TO SCALE. PLEASE |
| | DRAW THE LANDSCAPE PLAN AT THE SAME SCALE AS THE SITE |
| | PLAN. THE EXISTING LANDSCAPE PLAN IS NOT CONSISTENT |
| | WITH THE SITE PLAN REGARDING THE HARDSCAPE AND |
| | STRUCTURES. |
| | |
| | 2. SHOW ALL STREETS, UTILITIES, EASEMENTS, EXISTING |
| | TREES ON NEIGHBORING PROPERTY IN CLOSE PROXIMITY TO THE |
| | PROPERTY LINE THAT MAY IMPEDE THE GROWTH OF PROPOSED |
| | TREES, TRASH/GARBAGE AREAS WITH SCREENING, GROUND LEVEL |
| | AIR CONDITIONING UNITS AND OTHER MECHANICAL EQUIPMENT |
| | WITH SCREENING AND ANYTHING ELSE THAT MAY INTERFERE |
| | WITH THE PROPOSED LANDSCAPING. |
| | |
| | 3. PROVIDE ALL REQUIRED LANDSCAPE CALCULATIONS BASED |
| | UPON ARTICLE XIV OF THE ZONING AND LAND DEVELOPMENT |
| | REGULATIONS. |
| | |
| | 4. PROVIDE A LANDSCAPE PLANT LIST WITH ALL PROPOSED |
| | PLANT MATERIAL, SIZE (NOT CONTAINER SIZE) AND SPACING. |
| | |
| | 5. PROVIDE SOD AND IRRIGATION IN THE RIGHTS-OF-WAY. |
| | |
| | 6. SHOW THE VISIBILITY TRIANGLE. |
| | |
| | 7. TREES CANNOT BE PLANTED IN THE RIGHT-OF-WAY WITHOUT |
| | APPROVAL OF THE ENGINEERING DEPARTMENT. |
| | |
| | 8. IDENTIFY ALL EXISTING TREES ON SITE. IF ANY TREES |
| | WILL BE REMOVED, A TREE ALTERATION PERMIT APPLICATION |
| | SHALL BE REQUIRED. |
| | |
| | 9. NO SHADE TREES HAVE BEEN PROPOSED. ONE SHADE OR |
| | FLOWERING TREE SHALL BE PLANTED FOR EACH 1200 SQUARE |
| | FEET OF OPEN SPACE. |
| | |
| | |
| | |