| Date |
Text |
| 2008-07-10 13:28:56 | DENIED |
| | REFERENCE: FBC-2004 PLUMBING W/2007 AMENDMENTS |
| | FBC-2004 FUEL GAS W/2007 AMENDMENTS |
| | FBC-2004 CHAPTER 1 |
| | FLORIDA ADMINISTRATIVE CODE |
| | FLORIDA STATUES |
| | CITY WPB MUNICIPAL CODE |
| | |
| | ****FROM PREVIOUS REVEIW: |
| | |
| | 1. OK |
| | |
| | 2. ALL PME & SPC SHEETS SHALL INCLUDE THE CERTIFICATE |
| | OF AUTHORIZATION FOR THE ENGINEERING COMPANY IN THE |
| | TITLE BLOCK OF EACH SHEET. ALSO THE ADDRESS FOR |
| | CUBELLIS INC IN INDICATED AS 711 ATLANTIC AVENUE BOSTON |
| | MA. ON THE FLORIDA STATE DBPR WEBSITE WHICH DOES NOT |
| | REFLECT THE ADDRESS INDICATED IN THE TITLE BLOCK OF |
| | EACH SHEET. (97 LIBBEY INDUSTRIAL PARKWAY WEYMOUTH MA). |
| | PLEASE UPDATE THE TITLE BLOCK OR THE DBPR WEBSITE PRIOR |
| | TO RESUBMITTING TO THE CITY FOR REVIEW. (SEE ATTACHED |
| | SHEET). FAC 61G15-23.002(2) & FS 471.2055. ****RESPONSE |
| | NOTED, BUT THE ADDRESS LISTED FOR CA NUMBER 27279 IS |
| | 711 ATLANTIC AVE BOSTON WHICH DOES NOT REFLECT THE |
| | ADDRESS IN THE TITLE BLOCKS OF THE PME OR SPC SHEETS. |
| | (281 SUMMER ST OR 1800 ELLER DR). |
| | |
| | 3. OK |
| | |
| | 4. SHT P-2 DRAWING NOTES #11 AND WASTE PIPING PLAN |
| | PIPING TO & INCLUDING THE GREASE INTERCEPTOR ARE NOT |
| | APPROVED. ARTICLE III SECTION 90-124(7)(B). PLEASE |
| | CONNECT ROTISSERIE TO EXISTING GREASE SYSTEM TO CATCH |
| | MINIMUM AMOUNT OF GREASE. THE ROTISSERIE SHALL DRAIN |
| | INTO A CONTAINER WHICH SHALL CATCH THE GREASE AND BE |
| | DISPOSED OF PROPERLY WITH OUT DRAINING INTO THE |
| | SYSTEM. |
| | ****RESPONSE NOTED, BUT THE CITY MUNICIPAL CODE DOES |
| | NOT ALLOW FOR THE GREASE TRAP/INTERCEPTOR IN THE FOOD |
| | PREP AREA. ARTICLE III SECTION 90-124(7)(B) STATES |
| | "GREASE INTERCEPTORS (SEPARATORS, GREASE TRAPS) ARE TO |
| | BE INSTALLED OUTSIDE OF THE FOOD PREPARATION AREA WITH |
| | THE DISHWASHER VIA A SEPARATE LINE. UPON FURTHER |
| | INVESTIGATION, THE ROTISSERIE SHALL DRAIN WITH AN AIR |
| | GAP INTO THE GREASE WASTE SYSTEM VIA A FLOOR SINK PER |
| | SECTION 802.3.2. |
| | |
| | 5. OK |
| | 6. OK |
| | |
| | 7. SHT P-5 GREASE INTERCEPTOR AT ROTISSERIE IS NOT |
| | APPROVED. ARTICLE III SECTION 90-124(7)(B). |
| | ****RESPONSE NOTED, BUT THE CITY MUNICIPAL CODE DOES |
| | NOT ALLOW FOR THE GREASE TRAP/INTERCEPTOR IN THE FOOD |
| | PREP AREA. ARTICLE III SECTION 90-124(7)(B) STATES |
| | "GREASE INTERCEPTORS (SEPARATORS, GREASE TRAPS) ARE TO |
| | BE INSTALLED OUTSIDE OF THE FOOD PREPARATION AREA WITH |
| | THE DISHWASHER VIA A SEPARATE LINE. UPON FURTHER |
| | INVESTIGATION, THE ROTISSERIE SHALL DRAIN WITH AN AIR |
| | GAP INTO THE GREASE WASTE SYSTEM VIA A FLOOR SINK PER |
| | SECTION 802.3.2. |
| | |
| | 8. OK |
| | 9. OK |
| | |
| | 10 SHT P-6 A SEPARATE GAS PERMIT IS REQUIRED. SUBMIT |
| | THE FOLLOWING INFORMATION FOR PERMIT: |
| | |
| | A. OK |
| | |
| | B. TYPE OF GAS, (LP OR NATURAL). |
| | ****RESPONSE NOTED, BUT GAS TYPE NOT INDICATED. |
| | |
| | C. OK |
| | D. OK |
| | E. OK |
| | F. OK |
| | |
| | 11. SHT P-7 THE PLUMBING LEGEND AND SCHEDULE #50 AS |
| | WELL AS THE GREASE TRAP DETAIL ARE NOT APPROVED. |
| | ARTICLE III SECTION 90-124(7)(B). PLEASE DELETE FROM |
| | PLANS. |
| | ****RESPONSE NOTED, BUT THE CITY MUNICIPAL CODE DOES |
| | NOT ALLOW FOR THE GREASE TRAP/INTERCEPTOR IN THE FOOD |
| | PREP AREA. ARTICLE III SECTION 90-124(7)(B) STATES |
| | "GREASE INTERCEPTORS (SEPARATORS, GREASE TRAPS) ARE TO |
| | BE INSTALLED OUTSIDE OF THE FOOD PREPARATION AREA WITH |
| | THE DISHWASHER VIA A SEPARATE LINE. UPON FURTHER |
| | INVESTIGATION, THE ROTISSERIE SHALL DRAIN WITH AN AIR |
| | GAP INTO THE GREASE WASTE SYSTEM VIA A FLOOR SINK PER |
| | SECTION 802.3.2. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, |
| | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING |
| | THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE |
| | ALL VOID SHEETS FROM ALL PLANS AND PLACE |
| | ONE SET OF THEM LOOSELY ON TOP OF THE |
| | COLLATED PLANS TO BE REVIEWED. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 805-6731 |
| | E-MAIL [email protected] |