| Date |
Text |
| 2008-08-08 14:24:00 | BUILDING PLAN REVIEW |
| | PERMIT: 08040438 |
| | ADD: 420 6TH ST |
| | CONT: BENNARD SIMPSON G C |
| | TEL: (561) 296-5858 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | AUG.08-08 |
| | 3RD REVIEW |
| | ACTION: DENIED |
| | |
| | 1-9 COMPLIED. |
| | |
| | 10) SECOND REQUEST,FL BLD CODE 1609.1.4: |
| | COMPONENTS & CLADDING, PROVIDE 2 COPIES, 3 IF THRESHOLD |
| | OR RESIDENT INSPECTOR OF PRODUCT TESTING REPORTS, |
| | MISSING REPORTS ARE AS FOLLOWS: |
| | ROOFING ASSEMBLIES; |
| | 10A) FIRESTONE REPORT NOA05-0830.10-52.5 PSF & |
| | LIMITATION# 7 ENHANCED FASTENING ALLOWEDBUT NO RAS |
| | 117 CALCULATION PROVIDED. |
| | 10B) POLYGLASS COATING AND MASTICS FL# 10291/ |
| | NOA07-0919.04 REPORTSUBMITTED IS ONLY FOR COATING AND |
| | MASTICS SUB PARTS OF AN OVER ALL ROOFING ASSEMBLY. |
| | PRINTED OUT IS A FL COVER SHEET FOR THEPOLYGLASS |
| | SYSTEMS MODIFIED SYSTEMS AND UNDERLAYMENTS, NOTE, THESE |
| | SYSTEMS SHOULD NOT BE USED WITH A MODIFIED SYSTEM FROM |
| | FIRESTONE, POLYGLASS IS NOT PART OF ANY FIRESTONE |
| | SYSTEM.. |
| | |
| | 11-14) COMPLIED. |
| | |
| | 15) BUILDING PROVISO:109.3.10* IMPACT OF |
| | CONSTRUCTION. ALL CONSTRUCTION ACTIVITY REGULATED BY |
| | THIS CODE SHALL BE PERFORMED IN A MANNER SO AS NOT TO |
| | ADVERSELY IMPACT THE CONDITION OF ADJACENT PROPERTY, |
| | UNLESS SUCH ACTIVITY IS PERMITTED TO AFFECT SAID |
| | PROPERTY PURSUANT TO A CONSENT BY THE APPLICABLE |
| | PROPERTY OWNER, UNDER TERMS & CONDITIONS AGREEABLE TO |
| | THE APPLICABLE PROPERTY OWNER. THIS INCLUDES BUT IS NOT |
| | LIMITED TO THE CONTROL OF DUST, NOISE, WATER OR |
| | DRAINAGE RUN-OFF, DEBRIS, AND THE STORAGE OF |
| | CONSTRUCTION MATERIALS. NEW CONSTRUCTION ACTIVITY SHALL |
| | NOT ADVERSELY IMPACT HISTORIC SURFACE WATER DRAINAGE |
| | FLOWS SERVING ADJACENT PROPERTIES, & MAY REQUIRE |
| | SPECIAL DRAINAGE DESIGN COMPLYING WITH ENGINEERING |
| | STANDARDS TO PRESERVE THE |
| | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, |
| | DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW |
| | RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS, |
| | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING |
| | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ |
| | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A |
| | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED |
| | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS |
| | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A |
| | CERTIFICATION FROM A LICENSED ENGINEER SHALL BE |
| | SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL |
| | OF THE FINAL INSPECTION. |
| | |
| | 109.3.10.1 HURRICANE PROTECTION. IT SHALL BE |
| | UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION RELATED |
| | MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR |
| | OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 HRS. |
| | AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE |
| | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH |
| | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE |
| | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN |
| | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH |
| | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING |
| | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY |
| | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE |
| | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 |
| | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE |
| | SUBJECT TO A FINE NOT TO EXCEED $500.00.IN ADDITION |
| | TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS |
| | SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO |
| | SECTION 113 OF THIS CHAPTER. |
| | |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| 2008-07-01 10:52:24 | BUILDING PLAN REVIEW |
| | PERMIT: 08040438 |
| | ADD: 420 6TH ST |
| | CONT: BENNARD SIMPSON G C |
| | TEL: (561) 296-5858 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2NDREVIEW |
| | ACTION: DENIED |
| | |
| | 1A) PLEASE PROVIDE: WHEN RESUBMITTING PLANS PLEASE |
| | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | 1B-1E) COMPLIED. |
| | |
| | 2A-C ) COMPLIED. |
| | 3-5 ) 7-02-08 AS PER CONVERSATION WITH TONY ZIA |
| | DESIGNER WILL PROVIDE THE AMOUNT OF FLAMMABLE LIQUIDS |
| | THAT WILL BE STORED ON SITE FIRST FLOOR. THEY WILL |
| | DETERMINE THAT TIME IF CONTROLED AREAS WILL BE |
| | NECCESSARY SEE TABLE 307.7(1) FLAMMABLE LIQUIDS AND |
| | COMBUSTIBLE LIQUIDS. FERTILIZERS MAY ALSO BE A CONCERN |
| | AS TO CONTROL AREAS. THE SECOND FLOOR OFFICE AND |
| | WAREHOUSE AREA WILL ALSO NEED TO BE SEPERATED IN |
| | ACORDANCEWITH 302.2 THE OFFICE AREA BEING OVER THE |
| | 10% ALLOWABLE AREA TO BE CONSIDERED AN ACCESORY USE |
| | AREA.THE DESIGNERS WILL ALSO NEED TO PROVIDE WHAT |
| | TYPE GOODS WILL BE STORED IN THE SECOND FLOOR WAREHOUSE |
| | PORTION DECLARING EITHER A S1 OR S2 STORAGE AND THE |
| | REQUIRED OCCUPANCY SEPERATION DECLARED IN TABLE |
| | 302.3.2. NOTE THE BUILDING IS FULLY SPRINKLERED AND CAN |
| | TAKE A 1 HOUR REDUCTION TO THE SAID WALL 302.3.2.. |
| | |
| | 6) COMPLIED |
| | |
| | 7-9 COMPLIED. |
| | |
| | 10) SECOND REQUEST,FL BLD CODE 1609.1.4: |
| | COMPONENTS & CLADDING, PROVIDE 2 COPIES, 3 IF THRESHOLD |
| | OR RESIDENT INSPECTOR OF PRODUCT TESTING REPORTS, |
| | MISSING REPORTS ARE AS FOLLOWS: |
| | ROOFING ASSEMBLIES; |
| | 10A) FIRESTONE REPORT NOA05-0830.10-45 PSF & |
| | LIMITATION# 9 NO ENHANCED FASTENING ALLOWED |
| | 10B) POLYGLASS COATING AND MASTICS FL# 10291/ |
| | NOA07-0919.04 REPORTSUBMITTED IS ONLY FOR COATING AND |
| | MASTICS SUB PARTS OF AN OVER ALL ROOFING ASSEMBLY. |
| | PRINTED OUT IS A FLOVER PRINT OUT OF POLYGLASS SYSTEMS |
| | MODIFIED SYSTEMS AND UNDERLAYMENTS. |
| | |
| | 11)PRODUCT APPROVALS SUBMITTED WITH PERMIT |
| | APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED TO |
| | COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR |
| | INFORMATION PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE |
| | APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER |
| | SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, |
| | SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR |
| | SITE SPECIFIC FORM PER RULE 9B-72. SEE ATTACHMENT. |
| | WWW.FLORIDABUILDING.ORG |
| | |
| | 12)WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE |
| | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | 13) INFORMATIONAL, AWNING PERMITS REQUIRE A SEPERATE |
| | PERMIT. |
| | |
| | 14) COMPLIED. |
| | |
| | 15) BUILDING PROVISO:109.3.10* IMPACT OF |
| | CONSTRUCTION. ALL CONSTRUCTION ACTIVITY REGULATED BY |
| | THIS CODE SHALL BE PERFORMED IN A MANNER SO AS NOT TO |
| | ADVERSELY IMPACT THE CONDITION OF ADJACENT PROPERTY, |
| | UNLESS SUCH ACTIVITY IS PERMITTED TO AFFECT SAID |
| | PROPERTY PURSUANT TO A CONSENT BY THE APPLICABLE |
| | PROPERTY OWNER, UNDER TERMS & CONDITIONS AGREEABLE TO |
| | THE APPLICABLE PROPERTY OWNER. THIS INCLUDES BUT IS NOT |
| | LIMITED TO THE CONTROL OF DUST, NOISE, WATER OR |
| | DRAINAGE RUN-OFF, DEBRIS, AND THE STORAGE OF |
| | CONSTRUCTION MATERIALS. NEW CONSTRUCTION ACTIVITY SHALL |
| | NOT ADVERSELY IMPACT HISTORIC SURFACE WATER DRAINAGE |
| | FLOWS SERVING ADJACENT PROPERTIES, & MAY REQUIRE |
| | SPECIAL DRAINAGE DESIGN COMPLYING WITH ENGINEERING |
| | STANDARDS TO PRESERVE THE |
| | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, |
| | DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW |
| | RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS, |
| | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING |
| | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ |
| | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A |
| | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED |
| | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS |
| | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A |
| | CERTIFICATION FROM A LICENSED ENGINEER SHALL BE |
| | SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL |
| | OF THE FINAL INSPECTION. |
| | |
| | 109.3.10.1 HURRICANE PROTECTION. IT SHALL BE |
| | UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION RELATED |
| | MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR |
| | OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 HRS. |
| | AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE |
| | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH |
| | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE |
| | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN |
| | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH |
| | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING |
| | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY |
| | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE |
| | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 |
| | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE |
| | SUBJECT TO A FINE NOT TO EXCEED $500.00.IN ADDITION |
| | TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS |
| | SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO |
| | SECTION 113 OF THIS CHAPTER. |
| | |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |