| Date |
Text |
| 2008-07-07 08:06:12 | DENIED |
| | REFERENCE: FBC-2004 PLUMBING |
| | FBC-2004 CHAPTER 1 |
| | FBC-2004 CHAPTER 11 |
| | FBC-2004 BUILDING |
| | |
| | ****FROM PREVIOUS REVIEW: |
| | |
| | 1. OK |
| | 2. OK |
| | 3. OK |
| | 4. OK |
| | 5. OK |
| | 6. OK |
| | 7. OK |
| | |
| | 8. SUBMIT DETAILS AND ELEVATIONS FOR THE TOILET ROOM |
| | AND THE BATHROOM SHOWING COMPLIANCE WITH SECTIONS |
| | 11-4.16, 11-4.19, 11-4.21, 11-4.22 & 11-4.23 WITH ALL |
| | SUBSECTIONS AND FIGURES. INDICATE THE SIZE OF THE |
| | SHOWER. SEE SECTION 11-4.21.2 & FIG 35(A). ****RESPONSE |
| | NOTED, BUT SHOW COMPLIANCE FOR THE FOLLOWING: |
| | __FOR W/C'S: |
| | A. 11-4.16.5 FLUSH CONTROLS (TO THE WIDE SIDE) __FOR |
| | LAVS" |
| | A. 11-4.19.2 CLEARANCE (29" MIN. NOT MAX.) |
| | __FOR SHOWERS: |
| | A. 11-4.21.3 SEAT (HEIGHT) |
| | B. 11-4.21.5 CONTROLS |
| | C. 11-4.21.6 SHOWER UNIT |
| | D. 11-4.21.7 CURBS (1/2" MAX) |
| | |
| | 9. OK |
| | 10. OK |
| | 11. OK |
| | 12. OK |
| | |
| | 13. SHT A7.1.1 ROOM FINISH SCHEDULE FOR ROOM 246. SHOW |
| | COMPLIANCE WITH SECTION 1210.1 REQUIREMENT FOR FLOORS |
| | TO HAVE A SMOOTH, HARD, NONABSORBENT SURFACE. CARPET |
| | DOES NOT COMPLY WITH THESE REQUIREMENT. PLEASE SHOW |
| | COMPLIANCE. |
| | ****RESPONSE NOTED, BUT NOT INDICATED ON THE FINISH |
| | SCHEDULE. |
| | |
| | 14. OK |
| | 15. OK |
| | 16. OK |
| | |
| | 17. SUBMIT AN ISOMETRIC WATER RISER DIAGRAM FOR THE |
| | BREAK ROOM SINK, DRINKING FOUNTAINS, DISHWASHER ETC |
| | SHOWING ALL PIPE SIZES, VALVES AND , WHERE REQUIRED, |
| | WATER HAMMER ARRESTORS PER 604.9, (ANY ICE MAKERS, |
| | DISHWASHERS ETC), INSTALLED NEAR THE FIXTURES IN AN |
| | "EFFECTIVE RANGE" NOT IN THE CEILING. SECTIONS |
| | 106.3.5.1.3, 601.1, 604 - TABLE 604.5 & PDI-WH 201. |
| | ****RESPONSE NOTED, BUT WATER HAMMER ARRESTOR IS |
| | REQUIRED AT THE DISHWASHER BUT NOT SHOWN. |
| | |
| | 18. OK |
| | 19. OK |
| | 20. OK |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, |
| | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING |
| | THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE |
| | ALL VOID SHEETS FROM ALL PLANS AND PLACE |
| | ONE SET OF THEM LOOSELY ON TOP OF THE |
| | COLLATED PLANS TO BE REVIEWED. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 805-6731 |
| | E-MAIL [email protected] |