| 2008-04-17 15:40:34 | DENIED |
| | REFERENCE: FBC-2004 PLUMBING |
| | FBC-2004 CHAPTER 1 |
| | FBC-2004 CHAPTER 11 |
| | |
| | |
| | 1. PLANS SHALL BE DESIGNED TO FBC-2004 W/2007 |
| | AMENDMENTS. PLEASE INDICATE ON PLANS. SECTION 106.1.3. |
| | |
| | 2. THE CORRECT ADDRESS, (406 COLUMBIA DR), SHALL BE |
| | INDICATED ON THE TITLE BLOCK OF EACH SHEET. SECTION |
| | 106.1.1. |
| | |
| | 3. SHT D-1 INDICATES THE DEMOLITION/REMOVAL OF AN |
| | EXISTING 1 STORY BUILDING. THIS IS NOT INDICATED ON THE |
| | PERMIT APPLICATION WHICH STATES, "DESCRIBE PROJECT IN |
| | DETAIL". PLEASE INDICATE ALL MAJOR WORK FOR PROJECT ON |
| | THE APPLICATION. SECTION 105.1. |
| | |
| | 4. SHT A-1 PER TABLES 1004.1.2 & 403.1, ONE TOILET, ONE |
| | LAV, ONE SERVICE SINK AND ONE DRINKING FOUNTAIN ARE |
| | REQUIRED. ALSO SEE SECTION 411 AS ONE EMERGENCY EYE |
| | WASH OR EMERGENCY SHOWER MAY BE REQUIRED. PLEASE |
| | INDICATE THE LOCATION OF ALL FIXTURES REQUIRED. ALSO |
| | INDICATE THE TYPE AND AMOUNT OF MATERIALS BEING STORED |
| | AS WELL AS THE MSDS SHEETS FOR THE MATERIALS. SECTION |
| | 411. |
| | |
| | 5. AN RPZV BACKFLOW IS REQUIRED ON THE WATER SERVICE TO |
| | THE BUILDING. SECTION 608.13.2. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, |
| | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING |
| | THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE |
| | ALL VOID SHEETS FROM ALL PLANS AND PLACE |
| | ONE SET OF THEM LOOSELY ON TOP OF THE |
| | COLLATED PLANS TO BE REVIEWED. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |