| | BUILDING PLAN REVIEW |
| | PERMIT: 08040192 |
| | ADD: 1691 FORUM PL #B |
| | CONT: ABSOLUTE SIGN AND SERVICE |
| | TEL: (561)744-8030 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 4-19-08 |
| | REVIEW: 1ST |
| | ACTION: DENIED |
| | |
| | 1)1603.1.4. THE FOLLOWING INFORMATION RELATED TO WIND |
| | LOADS SHALL BE SHOWN, REGARDLESS OF WHETHER WIND LOADS |
| | GOVERN THE DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM |
| | OF THE BUILDING: |
| | A)BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR |
| | B)WIND IMPORTANCE FACTOR, I W , AND BUILDING |
| | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 |
| | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. |
| | C)WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS |
| | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND |
| | DIRECTION SHALL BE INDICATED |
| | D)THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF |
| | DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. |
| | E)COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES |
| | IN TERMS OF PSF TO BE USED FOR THE SELECTION OF |
| | EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT |
| | SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN |
| | PROFESSIONAL. A DESIGN PROFESSIONAL SHALL PROVIDE THE |
| | INOFRMATION FOR THE FASTNERS AND STRUCTURAL STABILITY |
| | OF THE SIGN. |
| | |
| | 2)INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST |
| | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO |
| | THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS. |
| | |