2008-04-30 17:56:54 
  
 DENIED
  
 THE FOLLOWING COMMENTS WERE NOT ADDRESSED ON THE 1ST
 REVIEW
  
 2)RAMPS ARE REQUIRED TO COMPLY WITH R311.6 OF THE FBC
 RES. MAX SLOPE OF 1 IN 8 (12.5%) PLEASE SEE ATTACHED
 CODE SECTION
 *****LOWER RAMP EXCEEDS 1 IN 12 AND WILL REQUIRE
 HANDRAIL PER R311.6.3 FBC*******
  
 3)PROVIDE SURVEY SHOWING LOCATION OF RAISED LANDING
 WITH ALL PROPERTY SETBACKS
  
  
 *******NOTE IF INDEED THE STOOP AT HOUSE IS APPROX 20"
 ABOVE GRADE AS SHOWN THE PROPOSED RAMP SHOULD COMPLY AT
 THE LENGTHS PROVIDED*****
  
 BLDG PLAN REVIEW