| 2008-04-08 13:51:35 | 2004 FBC W/2007 REVISIONS |
| | LEVEL 2 ALTERATION |
| | |
| | DENIED BY BUILDING |
| | |
| | 1) A NOTICE OF COMMENCEMENT WILL BE REQUIRED. |
| | |
| | 2) THE VALUE OF THE WORK IS TOO LOW. THE VALUE INCLUDES |
| | COST OF MATERIALS AS WELL AS LABOR AS WOULD BE CHARGED |
| | BY A CONTRACTOR. THE VALUE OF THE WORK HAS BEEN |
| | ADJUSTED TO $ 5595.00 BASED ON MARSHALL AND SWIFT |
| | ESTIMATING GUIDE. ADDITIONAL FEES OF $ 52.02 ARE DUE. |
| | |
| | 3) SPECIFY THE TYPE OF WINDOWS AT EACH LOCATION. |
| | PRODUCT APPROVALS WERE SUBMITTED FOR SINGLE HUNG AND |
| | FIXED WINDOWS. FBC 106.1.1* CITY AMENDMENTS |
| | |
| | 4) INDICATE THE LOCATIONS OF THE BEDROOMS ON THE FLOOR |
| | PLAN AND SHOW THAT THE EGRESS WINDOWS IN THOSE ROOMS |
| | HAVE NOT BEEN MADE ANY LESS SAFE BY REDUCING THE CLEAR |
| | OPENING SIZE. 2004 FBC EXISTING BUILDING SECTION |
| | 501.2. |
| | |
| | |
| | 5)OPENING #6 FOR THE NEW SLIDING GLASS DOOR IS |
| | SPECIFIED AS BEING WIDENED MORE THAN DOUBLE THE |
| | EXISTING OPENING SIZE. THIS DOES NOT CONCUR WITH THE |
| | PROCEDURES, WHICH SPECIFIES REMOVING THE BLOCK BELOW |
| | THE SILL. SUBMIT DRAWINGS THAT PROVIDE STRUCTURAL |
| | DETAILS OF THE NEW OPENING. FBC 106.1.1* CITY |
| | AMENDMENTS |
| | |
| | 6) BASED ON THE DIMENSIONS SUBMITTED THE OPENING HEIGHT |
| | FOR THE DOUBLE DOOR WILL NEED TO BE BUILT DOWN TO |
| | ACCOMMODATE THE DOORS. PROVIDE STRUCTURAL DETAILS. FBC |
| | 106.1.1* CITY AMENDMENTS |
| | |
| | 7) SUBMIT PRODUCT APPROVALS FOR THE STRUCTURAL |
| | MULLIONS. DCA RULE 9B-72. |
| | |
| | 8) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE |
| | PGT SLIDING GLASS DOOR ARE EXPIRED. SUBMIT CURRENT |
| | PRODUCT APPROVALS. DCA RULE 9B-72. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |
| | [email protected] |