2008-04-23 07:34:42BUILDING PLAN REVIEW
 PERMIT: 08040097
 ADD: 4720 N BROADWAY
 CONT: NUNNO BUILDERS
 TEL: (954)961-0777
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1A)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS,
 PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR
 SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL
 REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A
 THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN
 (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED
 FOR PERMIT ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS
 WEST PALM BEACH ADMINISTRATIVE CODE.
  
 1C)INFORMATIONAL106.1.1* W.P.B. ADMINISTRATIVE
 CODE/2004 DRAWINGS & SPECIFICATIONS SHALL CONTAIN
 INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO
 THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO
 CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION
 SHALL BE SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE
 CITED AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR
 ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1D ) INFORMATIONAL FL S S 713.13NOTICE OF
 COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT.
 NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLYCOMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL &
 VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 1E)INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST
 TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO
 THE 2004 FBC BUILDING WITH THE2007 SUPPLEMENTS PLEASE
 CORRECT THE PLANS NOW INDICATE THE 2006 SUPPLEMENTS.
  
 1F) PLANS FAIL TO MENTION THE DESIGN REQUIREMENTS OF
 THE EXISTING BUILD
 ING CODE, 2004 WITH 2007 SUPPLEMENTS.
  
 1G) PLANS INDICATE THIS TO BE A TYPE III BUILDING. THE
 RESPONSE SHEET INDICATES THE PLAN WAS CHANGED TO A V-B,
 BUT THEY CLEARLY STATE TYPE III BUT DO NOT INDICATE A
 OR B? TABLE 503, TABLE 601.
  
 1H)PLANS ALSO INDICATE THIS TO BE A LEVEL I
 ALTERATION. PLEASE SEE THE EXISTING BUILDING CODE
 SECTION 305, LEVEL 3 APPLY WHERE THE WORK AREA EXCEEDS
 50 PER CENT OF THE AGGREGATE AREA OF THE BUILDING AND
 MADE WITHIN ANY 12-MONTH PERIOD.
  
 2) FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, PROVIDE
 2 COPIES(3 IF THRESHOLD OR RESIDENT INSPECTOR) OF
 PRODUCT
 TESTING REPORTS, MISSING REPORTS ARE AS FOLLOWS: A)
 EFIS WALL SYSTEMS MISSING THE FLORIDA COVER SHEET/
 DESIGNER OF RECORD APPROVAL
 WITH SHOP DRAWING STAMP IS REQUIRED, 2 SETS OF
 PRODUCT APPROVALS ONLY ONE SUBMITTED.
  
 B) TRUSS ANCHORS NONE SUBMITTED WILL REQUIRE THE
 FLORIDA COVER SHEET/ DESIGNER OF
 RECORD APPROVALWITH SHOP DRAWING STAMP.
  
 C) ROOFING ASSEMBLIES- NONE SUBMITTED,THE FLORIDA
 COVER SHEET/ DESIGNER OF RECORD APPROVAL
 WITH SHOP DRAWING STAMP. SUBSYSTEMS ARE NOT
 HIGHLIGHTED. WILL REQUIRE ENHANCED
 FASTENING IN ZONES 2 & 3. PROVIDE RAS 117
 CALCULATIONS PER LIMITATION# 7.
  
 D) FIXED/ STOREFRONT WINDOWS-NONE WERE SUPPLIED.
 PROVIDETHE FLORIDA COVER SHEET/ PRODUCT TESTING
 SHEETS & DESIGNER OF RECORD APPROVALWITH SHOP DRAWING
 STAMP.
  
  
 3)PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION
 AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA PRODUCT
 APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE
 APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER
 SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL,
 SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR
 SITE SPECIFIC FORM PER RULE 9B-72.
  
 4) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 5A) 2ND REQUEST, SHEET A-4.1 INDICATES THE FRAMING
 DETAIL FOR THE NEWLY DESIGNEDTOWER, SHEET A-4.1
 INDICATES THE NEW TOWER HAS THE CENTER OPEN AND THE
 INSIDE WALLS HAVE A MODIFIED BITUMEN ROOFING MEMBRANE,
 THERE APPEARS TO BE NO ROOF DRAIN NOR OVERFLOW SCUPPERS
 TO ALLOW THE RAIN WATER OUT OF THIS BOX LOOKING TOWER.
 HOW WILL RAIN WATER BE DRAINED?
  
 5B) SHEET A.4.0, A.4.1 & A5.0 ALL SHOW THE PARAPET
 DETAILS, BUT NONE INDICATE HOW THE PARAPET WILL BE
 ATTACHED TO THE EXISTING STRUCTURE? 106.1.2*/ 1609 HOW
 WILL THE MOMENT OF OVERTURNING BE RESTRICTED?
  
 6) NOTE:COMPLIED CANOPY AND AWNINGS TO BE UNDER A
 SEPARATE PERMIT.A LETTER FROM THE OWNER (NOT TENANT)
 IS TO ACCOMPANY ALLFABRIC OR MEMBRANE-COVERED
 STRUCTURE DESIGNED WITH A QUICK REMOVAL OR BREAKAWAY
 MEMBRANE OR FABRIC TO ACKNOWLEDGE THEIR RESPONSIBILITY
 TO HAVE THE AWNING COVER REMOVED PRIOR TO ANY WIND
 EVENT WITH PROJECTED WIND SPEEDS OF 75 MPH OR GREATER.
 THE LETTER MUST BE SIGNED BY THE OWNER NOT TENANT.
 3105.4.2.1
 THE WIND DESIGN LOADS FOR ANY FABRIC OR
 MEMBRANE-COVERED STRUCTURE DESIGNED WITH A QUICK
 REMOVAL OR BREAKAWAY MEMBRANE OR FABRIC AT WIND
 VELOCITIES OF 75 MPH,
  
 7)SHEET A-4.1 WALL SECTION D AT CUPOLA,PLEASE
 CORRECT NOTATION TO DESIGN OF AWNING TO FBC CHAPTER
 43NOTE TO WHICH DESIGN THIS FABRIC CUPOLA WILL BE
 DESIGNED TO, 3105.4.2.1 OR 3105.4.2.2,
  
 A LETTER FROM THE OWNER (NOT TENANT) IS TO ACCOMPANY
 ALLFABRIC OR MEMBRANE-COVERED STRUCTURE DESIGNED WITH
 A QUICK REMOVAL OR BREAKAWAY MEMBRANE OR FABRIC TO
 ACKNOWLEDGE THEIR RESPONSIBILITY TO HAVE THE AWNING
 COVER REMOVED PRIOR TO ANY WIND EVENT WITH PROJECTED
 WIND SPEEDS OF 75 MPH OR GREATER. THE LETTER MUST BE
 SIGNED BY THE OWNER NOT TENANT.
 3105.4.2.1
 THE WIND DESIGN LOADS FOR ANY FABRIC OR
 MEMBRANE-COVERED STRUCTURE DESIGNED WITH A QUICK
 REMOVAL OR BREAKAWAY MEMBRANE OR FABRIC AT WIND
 VELOCITIES OF 75 MPH,
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved