2008-12-02 08:43:44DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 1. SHT P-1 SHOWS NEW HUB DRAINS, NEW FLOOR DRAIN, A NEW
 FIXTURE AND NEW VENT THRU ROOF. PLEASE SUBMIT A
 SANITARY RISER DIAGRAM AND IF RUN, A NEW WATER RISER
 DIAGRAM THAT REFLECTS THE FLOOR PLAN FOR THE NEW
 FIXTURES. IDENTIFY ALL FIXTURES TO BE DRAINED INTO THE
 HUB DRAINS. SECTION 106.3.5.1.3.
  
 2. SHT P-1 SHOW THE PIPING TO THE LAV ON THE FLOOR PLAN
 FOR IN THE NORTHERN MOST TOILET ROOM THAT REFLECTS THE
 SANITARY RISER DIAGRAM. SECTIONS 106.1.2 & 701.1.
  
 3. SHT P-1 THE EXISTING FLOOR PLAN SHOWS 2 MOP SINKS
 AND A WATER HEATER, BUT THE NEW FLOOR PLAN DOES NOT.
 WERE THE MOP SINKS AND THE WATER HEATER DELETED? MORE
 INFORMATION IS REQUIRED. SECTION 106.1.2. IF THESE
 FIXTURES HAVE NOT BEEN DELETED, THEN PLEASE SHOW THEM
 ON THE NEW FLOOR PLAN. SECTION 106.1.1.
  
 4. SHT P-1 P TRAPS ARE REQUIRED FOR EACH OF THE HUB
 TRAPS AND THEY SHALL CONNECT DIRECTLY TO THE VENTED
 LINE. SECTIONS 802.2 & 1002.1.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  