2008-06-18 16:00:01BUILDING PLAN REVIEW
 PERMIT: 08040069
 ADD: 1105 N DIXIE HWY
 CONT: VENTURA CONSTRUCTION CORP
 TEL: (561)937-1850
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1A-1D) COMPLIED.I
  
 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS SHEET A0 APPLICABLE
 CODES
 INDICATES 2006 PLEASE UPDATE.
  
 1F- 1J) COMPLIED.
  
 2) COMPLIED.
  
 3) SECOND REQUEST, PLANS INDICATE THIS BUILDING TO BE
 LOCATED ON LOT# 9 BUT THE BUILDING APPEARS TO BE AS
 WIDE AS THE LOT. PLEASE PROVIDE A COPY OF A RECORDED
 UNITY OF TITLE OR SEE ZONING ON THE 5TH FLOOR FOR A
 COPY OF THE UNITY OF TITLE FORM AND RECORD IT AT THE
 CLERK OF THE COURT, UNIFYING LOTS 7, 9 & 11. UNITY OF
 TITLE. THE PROPOSED BUILDING STRUCTURE TRANSGRESSES
 LEGAL BOUNDARY LINES BETWEEN THE LOTS WHICH COMBINE TO
 FORM 'THE SITE'. A 'UNITY OF TITLE' SHALL BE RECORDED
 AT THE COUNTY COURTHOUSE. SUBMIT A COPY OF THE RECORDED
 'UNITY OF OF TITLE' DOCUMENT SO THAT FBC TABLE 601
 BOUNDARY LINE REQUIREMENTS MAY BE DEEMED NOT
 APPLICABLE. SEE ATTACHED SHEETS FROM PAPA.
  
 4) COMPLIED.
  
 5) BUILDING PROVISO: NOTE AWNINGS REQUIRE A SEPERATE
 PERMIT. A LETTER FROM THE OWNER (NOT TENANT) IS TO
 ACCOMPANY ALL FABRIC OR MEMBRANE-COVERED STRUCTURE
 DESIGNED WITH A QUICK REMOVAL OR BREAKAWAY MEMBRANE OR
 FABRIC TO ACKNOWLEDGE THEIR RESPONSIBILITY TO HAVE THE
 AWNING COVER REMOVED PRIOR TO ANY WIND EVENT WITH
 PROJECTED WIND SPEEDS OF 75 MPH OR GREATER. THE LETTER
 MUST BE SIGNED BY THE OWNER NOT TENANT.
 3105.4.2.1
 THE WIND DESIGN LOADS FOR ANY FABRIC OR
 MEMBRANE-COVERED STRUCTURE DESIGNED WITH A QUICK
 REMOVAL OR BREAKAWAY MEMBRANE OR FABRIC AT WIND
 VELOCITIES OF 75 MPH,
  
 6) BUILDING PROVISO: SIGNS TO BE BY SEPERATE PERMIT.
  
 7A) COMPLIED.
  
 7B) SECOND REQUEST, NEW PARAPET WORK, NOT INDICATING
 WIND DESIGN, PLEASE PROVIDE THE FOLLOWING WIND
 INFORMATION IF THIS IS A NEW FEATURE :
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE
 BUILDING:
 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR
 (KM/HR).
 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING
 CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7
 AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. 3.
 WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS
 UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND
 DIRECTION SHALL BE INDICATED.
 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF
 DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT.
 5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES
 IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION
 OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT
 SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN
 PROFESSIONAL.
  
 8) COMPLIED
  
 9) DEPENDING ON THE LAST OCCUPANCY MAY REQUIRE IMPACT
 FEE REVIEW: BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY.
 THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE
 PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved