2008-05-06 14:40:40*****DENIED*****
  
  
 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.ADD
 NFPA 241 TO APPLICABLE CODES ON SHEET A-0
  
 2.ON SHEET A-0 UNDER THE APPLICABLE CODES, BE ADVISED
 THAT NFPA 72 IS A FIRE ALARM CODE.UNDER TYPE CHANGE
 FROM FIRE PREVENTION TO FIRE ALARM
  
 3.SHOW/DISPLAY THE NUMERICAL ADDRESS ON THE STRUCTURE
 OF EXTERIOR ELEVATION WHICH FRONTS NORTH DIXIE HIGHWAY.
 AS PER WEST PALM BEACH CODE, THE NUMBERS SHALL BE NO
 LESS THAN 6" IN HEIGHT AND NO LESS THAN 1" IN
 WIDTH/STROKE.PLEASE BE ADVISED THAT AWNINGS, SIGNS,
 AND/OR SECURITY SHUTTERS SHALL NOT OBSTRUCT VISIBILITY
 OF THE ADDRESS NUMBERS.
  
 4.ON SHEET A-0 IT IS STATED THAT TWO EXITS ARE
 PROVIDED, HOWEVER ONLY ONE EXIT (ON THE NORTH
 ELEVATION) IS SHOWN ON A-6/LIFE SAFETY PLAN SHEET. SHOW
 THE LOCATION OF THE SECOND EXIT
  
 5.PLEASE EXPLAIN HOW ACCESS IS MADE TO THE
 RECTANGULAR PORTION LOCATED AT THE SOUTHWEST CORNER OF
 THE STRUCTURE BEHIND THE COOLATTA/EXPRESSO STATION.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE APPROPIATE PLAN SHEET
 EACH ITEM WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS