2008-03-25 17:23:42 
  
 DENIED
  
 1)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL
 COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 &
 2007AMENDMENTS PER 106.1.1 FBC*
  
 2)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING
 MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF
 ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND
 STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE
 DRAWINGS
  
 3)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 4)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES
  
  
 NOTE: FEES ARE DUE IN THE AMOUNT OF $1076.60 FOR
 INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS
 REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW
  
 5)PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN
 COMPLIANCE WITH THE REQUIREMENTS OF R403.1 FBC RES.
  
 6)PROVIDE AT MINIMUM 1 ACCESSIBLE BATHROOM PER
 R322.1.1 FBC 29" CLEAR WITH DOOR OPEN 90 DEGREES
  
 7)SUBMIT 2 COPIES OF THE SIGNED AND SEALED ENGINEERED
 TRUSS DRAWINGS THAT COMPLY WITH R802.10.1 FBC WITH
 PERMIT APPLICATION OR BEFORE INSTALLATION THAT HAVE
 BEEN REVIEWED AND APPROVED BY THE DESIGNER OF RECORD
 8)PROVIDE NOTE FOR SHOWER DOORS TO BE SAFETY GLAZING
 PER R308.4 FBC RES.
  
 9)PROVIDE SIZE OF ROOF OVERHANG, ELEVATIONS SHOW A
 1'-0" OH AND THE ROOF PLAN SHOWS A 2'-0" OH,ALSO GIVE
 ROOF VENTILATION ON DRAWINGS THAT COMPLIES WITH R806.1
 & 806.2 FBC RES.
  
 10)BUILDING ELEVATION TO INCLUDE MEAN ROOF HEIGHT
  
 11)WINDOWS IN BEDROOMS SHALL MEET THE EMERGENCY
 EGRESS REQUIREMENTS OFR310 FBC RES. MIN. NET CLEAR
 OPENING OF 5 SQ.FT. ON GRADE FLOOR. MIN. NET CLEAR
 OPENING ALL OTHER FLOORS OF 5.7 SQ.FT. IN BOTH CASES
 THE MIN.NET CLEAR HEIGHT SHALL BE 24" AND THE NET CLEAR
 WIDTH SHALL BE 20" PLEASE NOTE THAT THE TYPE "B"
 WINDOWS DO NOT MEET THIS CRITERIA
  
 12)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF
 EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE
 SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES.
 ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG
  
 13)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 14)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL SHEETS WHEN AVAILABLE. THEY CAN
 BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG.WHEN
 AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE
 DENIED
  
 15)NO PRODUCT APPROVALS WERE SUBMITTED FOR WINDOWS,
 EXTERIOR DOORS.SLIDING GLASS DOOR,ROOFING, AND
 CONNECTORS AND STRAPS. IN LUE OF PRODUCT APPROVALS
 STRAPS/CONNECTORS MAY BE LISTED IN A SCHEDULE ON THE
 DRAWINGS COMPLETE WITH THE STATEWIDE PRODUCT APPROVAL
 NUMBERS OR SUBMIT SIMPSON TIE?S COMPLETE FLORIDA INDEX
 WITH CONNECTORS TO BE USED HIGHLIGHTED
  
 16)PERMIT APPLICATIONS WITH SHUTTERS REQUIRE A KEY
 PLAN (WITH EGRESS SHOWN), SHUTTER SCHEDULE AND THE
 PRODUCT APPROVALS. APPROVAL DRAWINGS SHALL BE MARKED
 FOR MOUNTING METHOD AND CONNECTION TYPE AND THE
 SCHEDULE FILLED OUT WITH ALL PERTINENT INFORMATION
 SPECIFIC TO THE SITE (TYPE OF CONSTRUCTION, MOUNTING
 CONNECTION METHOD, ANCHOR TYPE, SHUTTER SPAN (VERTICAL
 OR HORIZONTAL), ETC.) PLEASE SEE THE ATTACHED MEMO AND
 SCHEDULE.
  
 17)THE WINDOW SEAT AND FRONT PORCH ADDITION CANNOT BE
 PERMITTED DUE TO THE ALREADY NON COMPLIANT EXISTING
 FRONT SETBACK OF 20'-0" SEE ZONING COMMENTS
  
 18)CORRECT DRAWINGS TO REFLECT COMPLIANCE WITH
 13-602.1.C.1.1 FBC, 2 X 6 WALLS REQUIRE R19 INSULATION
  
 19)ROOF SHEATHING REQUIRES A MINIMUM OF 8D RING SHANK
 NAILS AT 6" OC EDGES & FIELD ZONES 1 & 2 AND 4" OC IN
 ZONE 3 WHEN IN 140 MPH OR GREATER WIND ZONES PER
 R803.2.3.1 FBC RES. (2006 AMENDMENT)
  
 20)CLARIFY SECTION 8/S2 ON SHEETS-1 AND SECTION 9/S2
 ON SHEET S-4
  
 21)
  
 22)SUBMIT A COPY OF THE RECORDED NOTICE OF
 COMMENCEMENT TO THE CONSTRUCTION SERVICES DEPARTMENT.
  
 REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS OF
 NEW DRAWINGS WITH REVISIONS AND INCLUDE 1 COPY OF THE
 OLD PAGES ONLY FOR REFERENCE.
  
  
 NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006&2007
 AMENDMENTS
 FBC* = WEST PALM BEACH ADMINISTRATIVE
 AMENDMENTS TO FBC
 FAC = FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
 FBC RES. = FLORIDA BUILDING CODE
 RESIDENTIAL 2004 W/2006&2007 AMENDMENTS
  