| 2008-05-02 18:02:03 | DENIED |
| | REFERENCE: FBC-2004 PLUMBING |
| | FBC-2004 CHAPTER 1 |
| | FBC-2004 CHAPTER 11 |
| | FLORIDA ADMINISTRATIVE CODE |
| | FLORIDA STATUTES |
| | |
| | ****FROM PREVIOUS REVIEW: |
| | |
| | 1. OK |
| | 2. OK |
| | 3. OK |
| | 4. OK |
| | |
| | 5. SHT D1.1 THE REMOVAL OF THE WOMEN'S TOILET ROOM IN |
| | EFFECT DECREASES THE ACCESSIBILITY OF THE BUILDING. |
| | SECTION 11-4.1.6(1)(A). THIS IS NOT ACCEPTABLE. PLEASE |
| | CHOOSE AN ALTERNATIVE SUCH AS A UNISEX TOILET ROOM OR |
| | ALTERING THE STALL IN THE EXISTING TOILET ROOM TO |
| | COMPLY WITH THE ACCESSIBLITY CODE. |
| | ****RESPONSE NOTED, BUT THE EXISTING STALL WITH THE LAV |
| | INSTALLED STILL DECREASES THE ACCESSIBILITY AS THE LAV |
| | NOW ENCROCHES INTO THE CLEAR FLOOR SPACE REQUIRED TO |
| | TRANSFER FROM THE WHEECHAIR ONTO THE WATER CLOSET. |
| | |
| | 6. SHTS D1.1 & PE1.0 IN THE REMOVAL OF ANY PART OF A |
| | DRAINAGE SYSTEM, DEAD ENDS SHALL BE PROHIBITED. SECTION |
| | 704.5. ALL DEMO'D/CAPPED LINES SHALL BE LEFT UNCOVERED |
| | UNTIL FIELD INSPECTOR INSPECTION & APPROVAL. PLEASE |
| | INDICATE ON PLANS. |
| | ****RESPONSE NOTED, BUT THE NOTE IS NOT STATED ON THE |
| | D1.1 SHEET. ALSO SHT D1.1 HAS NOT BEEN RESUBMITTED BUT |
| | IS INDICATED ON THE INDEX OF DRAWINGS SHT CS. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, |
| | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING |
| | THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE |
| | ALL VOID SHEETS FROM ALL PLANS AND PLACE |
| | ONE SET OF THEM LOOSELY ON TOP OF THE |
| | COLLATED PLANS TO BE REVIEWED. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 805-6731 |
| | E-MAIL [email protected] |