| 2008-03-18 12:38:49 | BUILDING PLAN REVIEW |
| | PERMIT: 08030285 |
| | ADD: 525 OKEECHOBEE BLVD #1010 |
| | CONT: PASS INTERNATIONAL |
| | TEL: (954)241-9000 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 3-18-08 |
| | REVIEW: 1ST |
| | ACTION: DENIED |
| | |
| | 1A)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER |
| | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC |
| | BUILDING WITH THE 2007 SUPPLEMENTS. PLANS INDICATE THE |
| | 2006 AMENDMENTS, PLEASE UPDATE. |
| | |
| | 3)INDICATE THE CORRECT SQUARE FOOTAGE OF THE PROJECT |
| | AREA (SPACE #1020). SHEET CVR BOTTOM RIGHT CORNER, THE |
| | AREA OF WORK STATES 2900 SQ.FT AND THE CALCULATION FOR |
| | THE OCCUPANT LOAD HAS 2648 SQ. FT. CLARIFY. |
| | |
| | 4)PROVIDE A FIRE SPRINKLER HEAD LAYOUT OR A FIRE |
| | SPRINKLER SCHEMATIC FOR THE NEW SPACE LAYOUT. THIS CAN |
| | BE SHOWN ON THE CEILING PLAN FBC 106.3.5.1.1(5) |
| | |
| | 5)THE SHELL BUILDING HAS NOT ACHIEVED A CERTIFICATE |
| | OF COMPLETION, THE CONTRACTOR FOR THIS TENANT SPACE IS |
| | DIFFERENT FROM THE ?BASE BUILDING? AND WILL BE REQUIRE |
| | A NOTARIZE LETTER FROM THE BASE BUILDING CONTRACTOR |
| | ALLOWING PASS INTERNATIONAL TO START WORK ON THIS |
| | TENANT SPACE BEFORE THE CO FOR THE BASE BUILDING HAS |
| | BEEN ISSUED. THE DEVELOPER AND BOTH G.C?S WILL HAVE TO |
| | SUBMIT A NOTARIZE LETTER STATING THAT THEY UNDERSTAND |
| | THAT ANY DISPUTE OVER RESPONSIBILITY DOES NOT RELIEVE |
| | THEM FROM THE JOINT RESPONSIBILITY TO COMPLY WITH THE |
| | BUILDING CODE. WPB AMENDMENTS 106.1.2 ADDITIONAL |
| | INFORMATION REQUIRED. |
| | |
| | 6)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC |
| | (BVD) MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| | PER 108.3 FBC* |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | [email protected] |
| | |