| Date |
Text |
| 2008-04-07 14:04:30 | *****DENIED***** |
| | |
| | 01.THE CORRECT ADDRESS, 2401 NORTH DIXIE HIGHWAY (NOT |
| | 2401 - 2405), OF THE NEW PROJECTED SITE SHALL BE IN THE |
| | TITLE BLOCK OF EACH SUBMITTED PLAN SHEET. |
| | |
| | 02.ON THE COVER PAGE, THE BUILDING SHOULD BE LOCATED |
| | BETWEEN 23RD STREET AND NORTHWOOD ROAD;NOT 24TH |
| | STREET AND 25TH STREET AS INDICATED ON THE SITE PLAN OR |
| | NW 24TH STREET AND 25TH STREET AS INDICATED ON THE |
| | LOCATION PLAN. |
| | |
| | 03.PLEASE SHOW/DISPLAY THE NUMERICAL ADDRESS ON THE |
| | APPROPIATE EXTERIOR ELEVATION WHICH FRONTS NORTH DIXIE |
| | HIGHWAY.AS PER WEST PALM BEACH CODE, THE NUMBERS |
| | SHALL BE NO LESS THAN SIX INCHES IN HEIGHT AND NO LESS |
| | THAN ONE INCH IN WIDTH/STROKE. |
| | |
| | 04.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR |
| | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. |
| | |
| | 05.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS |
| | SHALL BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT |
| | OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. |
| | |
| | 06.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE |
| | REFERENCED.THE GUIDELINES OF CHAPTER 38 (NEW BUSINESS |
| | OCCUPANCIES) WILL BE USED. |
| | |
| | 07.SPECIFY THE INTERIOR WALL AND CEILING FINISH |
| | MATERIALS IN TERMS OF CLASS A, CLASS B, OR CLASS C. |
| | |
| | 08.PROVIDE LIFE SAFETY / TRAVEL DISTANCE TO THE |
| | EXITS. |
| | |
| | 09.SHOW THE LOCATION OF THE 2A:10BC RATED FIRE |
| | EXTINGUISHER(S) WHICH SATISFY THE 75' TRAVEL DISTANCE. |
| | |
| | 10.IN REFERENCE TO THE REAR EXIT DOOR THAT LEADS TO |
| | AN EXIT ACCESS CORRIDOR, VERIFY THE FOLLOWING:A.) THE |
| | DOOR LEADING TO THE CORRIDOR SHALL BE AN APPROVED, |
| | LISTED, AND LABELED FIRE DOOR & ASSEMBLY IN ACCORDANCE |
| | WITH THEBREQUIREMENTS OF NFPA 80.(B) DURING ITS SWING |
| | , ANY DOOR IN A MEANS OF EGRESS SHALL LEAVE NOT LESS |
| | THAN ONE-HALF THE REQUIRED WIDTH OF THE AISLE, |
| | CORRIDOR, A PASSAGEWAY, OR A LANDING.(C)THE ADDRESS |
| | NUMBER SHALL BE POSTED ON THE EXTERIOR DOOR OF THE |
| | SPACE. |
| | |
| | |
| | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE |
| | LETTER INDICATING WHERE ON THE APPROPIATE PLAN SHEET |
| | EACH COMMENT WAS ADDRESSED |
| | |
| | |
| | CAPT. MICHAEL A. WILLIAMS |
| | FIRE PLAN REVIEW |
| | 561-805-6722 |