| 2008-04-29 10:56:58 | BUILDING PLAN REVIEW |
| | PERMIT: 08030020 |
| | ADD: 700 S ROSEMARY AVE #110 |
| | CONT: RUSSCO INC. GENERAL CONTRACTORS |
| | TEL: (508)989-3077/ NEYITA 856-6655 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2NDREVIEW |
| | ACTION: DENIED |
| | DATE: APRIL 29,2008 |
| | |
| | 1) COMPLIED. |
| | |
| | 2) 2ND REQUEST,THE BUILDING OFFICIAL HAS DETERMINED |
| | THAT THE CBC RUSSCO INC. GENERAL CONTRACTORS ARE |
| | WORKING OUT OF THE SCOPE OF THEIR LICENSE. FL S S |
| | 489.105 (B) |
| | BUILDING CONTRACTOR" MEANS A CONTRACTOR WHOSE |
| | SERVICES ARE LIMITED TO CONSTRUCTION OF COMMERCIAL |
| | BUILDINGS AND SINGLE-DWELLING OR MULTIPLE-DWELLING |
| | RESIDENTIAL BUILDINGS, WHICH COMMERCIAL OR RESIDENTIAL |
| | BUILDINGS DO NOT EXCEED THREE STORIES IN HEIGHT, AND |
| | ACCESSORY USE STRUCTURES IN CONNECTION THEREWITH OR A |
| | CONTRACTOR WHOSE SERVICES ARE LIMITED TO REMODELING, |
| | REPAIR, OR IMPROVEMENT OF ANY SIZE BUILDING IF THE |
| | SERVICES DO NOT AFFECT THE STRUCTURAL MEMBERS OF THE |
| | BUILDING. SHEET S01.1 & S02.1 BOTH INDICATE STRUCTURAL |
| | MEMBERS THAT WILL AFFECT THE STOREFRONT SYSTEM AND THUS |
| | THE BUILDING ENVELOPE ITSELF. |
| | RESPONSE INDICATES THAT THE CBC HAS APPLIED FOR THE |
| | ADDITIONAL LICENSE REQUIRED. UNTIL THE CGC ICENSE HAS |
| | BEEN ISSUED WE CAN NOT ISSUE THE PERMIT TO THE CBC. |
| | |
| | A SOLUTION IS TO HAVE A CGC PULL A SUB-PERMIT FOR THE |
| | INSTALLATION OF THE STOREFRONT SYSTEM AND HAVE THE CBC |
| | REMOVE THE STOREFRONT SYSTEM FROM THEIR SCOPE OF WORK. |
| | THIS HAS BEEN AN AVENUE USED BY OTHER CONTRACTORS THAT |
| | WERE IN THE SAME LICENSING SITUATION. |
| | |
| | |
| | 3) 2ND REQUEST, PRODUCT APPROVALS SUBMITTED WITH PERMIT |
| | APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED TO |
| | COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR |
| | INFORMATION PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE |
| | APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER |
| | SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, |
| | SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR |
| | SITE SPECIFIC FORM PER RULE 9B-72. |
| | |
| | KAWNEER350-MS, REQUIRES FLORIDA COVERSHEET, COMMENT |
| | FROM THE LAST REVIEW, THE SITUATION AT HAND, THE BATH & |
| | BODY WORKS COVERSHEET LIST 2 KAWNEER FLORIDA |
| | COVERSHEETS AND THE CORRESPONDING MIAMI-DADE NOA'SFL |
| | 627 FOR STOREFRONT AND THE SECOND IS FL 629 FOR |
| | STOREFRONT SWINGING DOOR.BOTH OF THESE NUMBERS ARE |
| | UNDER THE 2001 FBC NOT THE CURRENT 2004 FBC. PLEASE |
| | REMOVE THESE NUMBERS FROM THE PLAN DOCUMENTS. THE TWO |
| | MIAMI-DADE NOA'S THAT WERE SUBMITTED CAN BE USED AS |
| | LOCAL PRODUCT APPROVALS SINCE MIAMI-DADE HAS THEIR OWN |
| | THIRD PARTY QUALITY ASSURANCE PROGRAM. THE ISSUE IS THE |
| | KANEER NOA 04-0329.03 DOES HAVE THE DESIGNERS WRITTEN |
| | APPROVAL ON THE FRONT PAGE OF THE REPORT WHERE AS THE |
| | ARCH ALUMINUM NOA 05-0906.05 IS NOT SPECED IN FOR THE |
| | JOB, A KAWNEER STOREFRONT SYSTEM IS SPECKED IN UNDER |
| | THE NOA 02-0220.01, THIS NOA HAS EXPIRED ON 8-29-07, |
| | NOT CURRENT REPORT. |
| | |
| | A SOLUTION. THE ARCH ALUMINUM MIAMI-DADE NOA 05-0906.05 |
| | IS A CURRENT REPORT, IT MEETS THE WIND PRESSURES AND |
| | CAN BE A LOCAL PRODUCT APPROVAL WITH THE MIAMI-DADE |
| | THIRD PARTY QUALITY ASSURANCE PROGRAM. TWO ISSUES WILL |
| | NEED TO BE ADDRESSED. |
| | 1) THE DESIGN TEAM WILL NEED TO REVIEW THIS NOA FOR |
| | CODE COMPLIANCE THEN APPLY THEIR SHOP DRAWING STAMP IF |
| | APPROVED. |
| | 2) THE MIAMI-DADE NOA WOULD SECOND NEED TO BE |
| | REVIEWED BY CAPRI ENGINEERING FOR CODE COMPLIANCE, IF |
| | FOUND CODE COMPLIANT, STAMP AND SUBMIT TO THE BUILDING |
| | DEPARTMENT. |
| | |
| | IN REVIEWING THESE OPTIONS WITH THE BUILDING OFFICIAL |
| | HE HAS AGREED THAT AS FAR AS THE "BUILDING REVIEW" WE |
| | COULD ISSUE A PERMIT WITHOUT A THIRD AUDIT. ONLY ITEMS |
| | TO BE CORRECTED WOULD BE |
| | 1) CGC TO TAKE ON THE RESPONSIBILITY OF THE STOREFRONT |
| | SYSTEMS, THE NOA'S THAT ARE FOUND TO BE CODE COMPLIANT |
| | WITH THE DESIGN TEAMS APPROVAL AND CAPRI'S APPROVAL |
| | COULD THEN BE ISSUED. |
| | 2) THE CBC ON THEIR APPLICATION WOULD NEED TO IDENTIFY |
| | INTERIOR WORK ONLY, AND BUILDING COULD THEN CHANGE THIS |
| | REVIEW INTO A PASSED. |
| | |
| | 4-7) COMPLIED. |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |