| Plan Review Notes For Permit 08020670 |
| Permit Number |
08020670 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2008-03-10 16:03:49 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.DOCUMENTS PREPARED BY AN ARCHITECT AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS FS481. | | | | | | 2.PROVIDE A CODE SUMMARY; BUILDING TYPE FBC6, | | | BUILDING HEIGHT AND AREA FBC5, SPRINKLER INFORMATION, | | | OCCUPANCY CLASSIFICATION FBC 3, AREA PER OCCUPANCY, | | | OCCUPANT LOAD. | | | | | | 3.PROVIDE DIMENSIONS OF CORRIDORS. | | | | | | 4.THE PROPOSED EGRESS DOORS ARE OBSTRUCTED BY OTHER | | | DOORS.SEE FBC1003.6. | | | | | | 5.SEE FBC1004.1 .NOTE THAT YOU PROPOSE TO REDUCE | | | THE CLEAR WIDTH OF A COMPONENT OF MEANS OF EGRESS. | | | CODE COMPLIANCE MUST BE DEMONSTRATED. | | | |
|