2008-03-10 10:52:372004 FBC W/2007 REVISIONS
 LEVEL 2 ALTERATIONS AND ADDITION
  
 DENIED BY BUILDING
  
 1) A COPY OF THE RECORDED NOTICE OF COMMENCEMENT WILL
 BE REQUIRED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) SUBMIT A SURVEY/SITE PLAN SPECIFYING THE DISTANCES
 OF THE ADDITION TO PROPERTY LINES.
  
 4) IF LESS THAN 6 FEET TO THE PROPERTY LINES, THE SITE
 PLAN WILL NEED TO SPECIFY THAT THE DISTANCE TO ANY
 STRUCTURES ON THE ADJACENT PROPERTY IS MORE THAN 6 FEET
 OR SHOW COMPLIANCE WITH R302.1 AND R302.2. R302.1
 EXTERIOR WALLS SEPARATED BY LESS THAN 6 FEET (1828 MM)
 SHALL HAVE NOT LESS THAN A ONE-HOUR FIRE-RESISTIVE
 RATING WITH EXPOSURE FROM BOTH SIDES. PROJECTIONS SHALL
 NOT EXTEND TO A POINT CLOSER THAN 4 FEET (1220 MM) FROM
 AN ADJACENT PROJECTION OR WALL. R302.2 OPENINGS SHALL
 NOT BE PERMITTED IN THE EXTERIOR WALL OF A DWELLING OR
 ACCESSORY BUILDING THAT IS SEPARATED FROM AN ADJACENT
 BUILDING BY A DISTANCE OF LESS THAN 6 FEET (1828 MM).
 THIS DISTANCE SHALL BE MEASURED PERPENDICULAR TO THE
 LINE USED TO DETERMINE THE SEPARATION DISTANCE.
  
 5) THE DESIGN DATA ON SHEET 1 INCORRECTLY SPECIFIES
 ASCE 7-98. THE EDITION REFERENCED BY THE 2004 FBC IS
 ASCE 7-02. PLEASE CORRECT.
  
 6) THE ROOF PITCH ON SHEET 1 SPECIFIES A FLAT ROOF AND
 THE PLANS INDICATE A SLOPED ROOF. SPECIFY THE ROOF
 SLOPE ON THE PLANS. FBC 106.1.1* CITY AMENDMENTS.
  
 7) SPECIFY THE REQUIRED SOIL BEARING CAPACITY OF THE
 SOIL ON THE PLANS. FBC 106.1.1* CITY AMENDMENTS.
  
 8) REVISE THE ROOF SHEATHING FASTENING NOTES ON THE
 TYPICAL WALL SECTION ON SHEET 5 TO COMPLY WITH
 R803.2.3.1 WHICH REQUIRES 8D RING-SHANK NAILS.
  
 9) SUBMIT TWO (2) COPIES OF THE PRODUCT APPROVALS
 REQUIRED BY DCA RULE 9B-72. FBC 106.1* CITY
 AMENDMENTS.
  
 10) SUBMIT PRODUCT APPROVALS FOR THE STRUCTURAL WINDOW
 MULLIONS. DCA RULE 9B-72.
  
 11)FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS.
 THOSE PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 12) THE PRESSURES SPECIFIED IN THE NOA FOR THE SINGLE
 HUNG WINDOWS WITH DSB ANNEALED GLASS ARE TOO LOW FOR
 THE SH34 WINDOWS. ONE OF THE OTHER TYPE OF GLAZING
 LISTED IN THE CHART ON PAGE 1 OF THE NOA MUST BE USED.
  
 13)SUBMIT 2 COPIES OF A KEY PLAN AND INSTALLATION
 SCHEDULE FOR THE STORM PANELS. SPECIFY THE MOUNT TYPE,
 FASTENER TYPE AND SPACING, EDGE DISTANCE, GLASS
 SEPARATION, ETC. SEE SAMPLE OF SCHEDULE ATTACHED. FBC
 106.1.1* CITY AMENDMENTS.
  
 14) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY
 CALCULATION FORMS. SUBMIT TWO COPIES OF ENERGY CALCS.
 FBC 13-600.
  
  