Plan Review Notes
Plan Review Notes For Permit 08020529
Permit Number 08020529
Review Stop P
Sequence Number 1
Notes
Date Text
2008-02-26 13:21:21DENIED;
 1. WATER HEATER DETAILS; SHOW TYPE OF THERMAL EXPANION
 TO BE USED PER FBC PLUMBING SECTION 607.3. IF A HEATER
 PAN IS USED ON FIRST FLOOR PAN DRAIN IS REQUIRED AND
 MUST GO TO OUT SIDE SECTION 504.7.2.
 2. AUTOMATIC CLOTHES WASHER BRANCH DRAIN TO BE 3" TO
 SANITARY TEE SECTION 406.3.
 3. WATER RISER DIAGRAM; ONLY ON WATER HEATER SHOWN. T &
 P DISCHARGE PIPE TO BE 3/4"( ON HEATER SHOWN.) SHOCK
 ARRESTORS ARE NOT REQUIRED ON ALL FIXTURES SEE SECTION
 604.9
 PLUMBING PLAN REVIEW BY
 JOHN LEECH
 805-6695