2008-04-09 11:48:20****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1. CERTIFICATE OF AUTHORIZATION REQUIRED TO PRACTICE
 ARCHITECTURE THROUGH A COMPANY, FS481.219(2).
 APPLICATION IS IN PROGRESS; THIS MUST BE APPROVED AND
 THE CERTIFICATE OF AUTHORIZATION NUMBER PRINTED ON EACH
 SHEET PRIOR TO PERMIT ISSUANCE FAC61G1-16.004.
  
 2. THE VALUE HAS BEEN ADJUSTED.ALSO NOTE THAT THE
 VALUE OF THE SHELL BUILDING HAS BEEN ADJUSTED BASED ON
 ICC VALUATION TABLES, SEE ATTACHED.ADDITIONAL FEES
 ARE REQUIRED FOR BOTH THE SHELL BUILDING AND THIS
 PERMIT; PLEASE PAY IMMEDIATELY.NOTE THAT INSPECTIONS
 CANNOT BE SCHEDULED FOR THE ISSUED PERMIT UNTIL FEES
 ARE PAID.THE VALUATION DECLARED BY ORIGINAL
 CONTRACTOR WAS TOO LOW.
  
 3. A1, NOTE N1, NOTE IS INCOMPLETE.
  
 4. A1, CONDITION TYPES, STATES THAT PLYWOOD WILL BE
 INSTALLED 6IN ABOVE THE CEILING.SEE FBC603,
 COMBUSTIBLES NOT PERMITTED IN TYPE I AND II BUILDINGS.
 THIS DOES NOT APPEAR TO FALL UNDER ANY OF THE
 EXEMPTIONS.
  
 5. EXISTING ENTRY RAMP, SPECIFY SLOPE, FBC11-4.3.
  
 6. ELEVATION 5 A6 WATER FOUNTAIN CONFLICTS WITH 3A17
 AND FLOOR PLAN.
  
 7. 8 17, URINAL, SEE FBC11-4.18.2, SHOULD BE 17INCHES.
 SEE PLUMBING COMMENTS.
  
 8. THE SHELL BUILDING HAS NOT ACHIEVED A CERTIFICATE OF
 COMPLETION; THE CONTRACTOR FOR THIS TENANT SPACE IS
 DIFFERENT FROM THE BASE BUILDING AND WILL REQUIRE A
 LETTER FROM THE BASE BUILDING CONTRACTOR ALLOWING THE
 TENANT BUILDOUT CONTRACTOR TO START WORK ON THIS TENANT
 SPACE BEFORE THE C OF C FOR THE BASE BUILDING HAS BEEN
 ISSUED.THE DEVELOPER AND BOTH CONTRACTORS WILL BE
 REQUIRED TO SUBMIT A LETTER STATING THAT THEY
 UNDERSTAND THAT ANY DISPUTE OVER RESPONSIBILITY DOES
 NOT RELIEVE THEM FROM THE JOINT RESPONSIBILITY TO
 COMPLY WITH THE BUILDING CODE.
  
 9. FIRE SPRINKLER PLANS REQUIRED IF SPRINKLERS ARE
 REQUIRED FOR CODE COMPLIANCE, FBC*106.3.5.1.1(5),
 FS553.79 (2).PLEASE ADVISE IF A FIRE SPRINKLER PERMIT
 HAS ALREADY BEEN ISSUED.
  
 10. DECLARE MAXIMUM RACK HEIGHT ON THE PLAN.
  
 11.SEE ELECTRIC COMMENTS REGARDING ENERGY CALC
 VERSION.PLEASE CONFIRM ALL BUILDING COMPONENTS SUCH
 AS WINDOWS, DOORS, HOT WATER HEATER, INSULATION, ETC.
 FOR INSTANCE, NO HOT WATER HEATER IS SHOWN AND GLASS
 STOREFRONT IS NOT REFLECTED IN THE ENERGY CALC DOOR AND
 WINDOW DATA.THIS IS A STATUTORY AND FLORIDA BUILDING
 CODE REQUIREMENT.