2008-02-11 22:55:15BUILDING PLAN REVIEW
 PERMIT: 08010137
 ADD: 9847 OKEECHOBEE BLVD
 CONT: TRINITY RETAIL CONSTRUCTION
 TEL: (772)834-8021
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
  
 1A)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS,
 REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR
 REVIEW FOR PERMIT.
 IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF
 YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A
 THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID
 DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1*
 /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH
 ADMINISTRATIVE CODE.
  
 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS
 A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND
  
 SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS
 OF THIS CODE AND RELEVANT LAWS, ORDINANCES, RULES AND
 REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL.
  
 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS, PLEASE UPDATE
 PLANS.
  
 2) PLEASE REVIEW ALL SHEETS OF THE PLANS AND CORRECT
 THE ADDRESS OF THE JOBSITE, MANY INDICATE WORK TO BE
 COMPLETED UNDER THIS PERMIT IS AT 4354 OKEECHOBEE
 BLVD.
  
 3) THE SHELL PERMIT IS NOT YET RECEIVED A ISSUED
 PERMIT. PLEASE SEE THE ELECTRICAL COMMENT NUMBER ONE
 WHICH DEALS WITH DIFFERENT DESIGN TEAMS FROM THE BASE
 BUILDING AND SHOP DRAWING STAMP APPROVAL FROM THE BASE
 BUILDING DESIGN TEAM.
  
 4) THE BASE BUILDING CONTRACTOR WILL ALSO NEED TO
 PROVIDE A LETTER TO ALLOW THE TENANT FIT UP CONTRACTOR
 TO START WORK BEFORE THE ISSUANCE OF ACERTIFICATE OF
 COMPLETIONTHIS WILL BE REQUIRED TO BE NOTARIZED
 LETTER.
  
 5) NOTE, SIGN PERMITS UNDER A SEPARATE PERMIT.WEST PALM
 BEACH ADMINISTRATIVE CODE
 105.1.
  
 6)SHEET A-6 DETAIL# 14 INDICATES THE USE OF WOOD BUCKS,
 PLEASE NOTE THE BUILDING CLASSIFICATION TYPE II-B
 SECTION 603.1 (1) FIRE RETARDANT TREATED WOOD CAN BE
 USED IN NON-BEARING PARTITIONS, PLEASE CORRECT WOOD
 BUCKS TO FIRE RETARDANT TREATED WOOD.
  
 7) SHEET A-6 PARTITION GENERAL NOTE (6) INDICATES THE
 USE OF WATER RESISTANT GYPSUM BOARD ALL WET AREAS,
 PLEASE SEE 1210.2 FOR WALLS WITHIN 2?-0? OF WATER
 CLOSETS, URINALS SHALL HAVE A SMOOTH, HARD,
 NONABSORBENT SURFACE TO A HEIGHT OF 4?-0?.
  
 8)NOTE THE MEP SHEETS THE ENGINEERING FIRM IS MISSING
 THEIR CERTIFICATE OF AUTHORIZATION. FLORIDA S. S.
 471.023 CERTIFICATE OF AUTHORIZATION.THE TITLE BLOCK
 FOR ANY SHEET BEARING THE NAME OF AN ENGINEER
 PRACTICING UNDER A FICTITIOUS NAME, A
 CORPORATION, OR A PARTNERSHIP, OFFERING ENGINEERING
 SERVICES, SHALL INCLUDE THE CERTIFICATE OF
 AUTHORIZATION NUMBER. ADD THE NUMBER TO EACH SHEET.
 THIS MAY BE ADDED BY HAND.
  
 9) CODE DATA COVER SHEET INDICATES AN OCCUPANT LOAD OF
 124 REQUIRING 2 EXITS ASA STATED IN THE CODE ANALYSIS,
 PLEASE LOOK AT SHEET A-3 INDICATING AT THE REAR OF THE
 SHOW ROOM AN EXIT LIGHT FOR THE 2ND EXIT.PLEASE
 CORRECT NOTE ON SHEET A-1 REAR SET OF DOORS REMOVE
 ENTRY /EXIT HARDWARE AND LOCK SHUT!!!!!!! TABLE 1014.1
 MERCANTILE OCCUPANT LOADS >50 REQUIRE 2 MEANS OF
 EGRESS.
  
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved