| Date |
Text |
| 2008-02-11 22:55:15 | BUILDING PLAN REVIEW |
| | PERMIT: 08010137 |
| | ADD: 9847 OKEECHOBEE BLVD |
| | CONT: TRINITY RETAIL CONSTRUCTION |
| | TEL: (772)834-8021 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW |
| | ACTION: DENIED |
| | |
| | |
| | 1A)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS, |
| | REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR |
| | REVIEW FOR PERMIT. |
| | IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF |
| | YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A |
| | THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID |
| | DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* |
| | /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH |
| | ADMINISTRATIVE CODE. |
| | |
| | 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 |
| | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN |
| | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF |
| | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY |
| | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE |
| | SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS |
| | A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS |
| | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE |
| | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| | EXTENT OF THE WORK PROPOSED AND |
| | |
| | SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS |
| | OF THIS CODE AND RELEVANT LAWS, ORDINANCES, RULES AND |
| | REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL. |
| | |
| | 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE |
| | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT |
| | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) |
| | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC |
| | BUILDING WITH THE 2007 SUPPLEMENTS, PLEASE UPDATE |
| | PLANS. |
| | |
| | 2) PLEASE REVIEW ALL SHEETS OF THE PLANS AND CORRECT |
| | THE ADDRESS OF THE JOBSITE, MANY INDICATE WORK TO BE |
| | COMPLETED UNDER THIS PERMIT IS AT 4354 OKEECHOBEE |
| | BLVD. |
| | |
| | 3) THE SHELL PERMIT IS NOT YET RECEIVED A ISSUED |
| | PERMIT. PLEASE SEE THE ELECTRICAL COMMENT NUMBER ONE |
| | WHICH DEALS WITH DIFFERENT DESIGN TEAMS FROM THE BASE |
| | BUILDING AND SHOP DRAWING STAMP APPROVAL FROM THE BASE |
| | BUILDING DESIGN TEAM. |
| | |
| | 4) THE BASE BUILDING CONTRACTOR WILL ALSO NEED TO |
| | PROVIDE A LETTER TO ALLOW THE TENANT FIT UP CONTRACTOR |
| | TO START WORK BEFORE THE ISSUANCE OF ACERTIFICATE OF |
| | COMPLETIONTHIS WILL BE REQUIRED TO BE NOTARIZED |
| | LETTER. |
| | |
| | 5) NOTE, SIGN PERMITS UNDER A SEPARATE PERMIT.WEST PALM |
| | BEACH ADMINISTRATIVE CODE |
| | 105.1. |
| | |
| | 6)SHEET A-6 DETAIL# 14 INDICATES THE USE OF WOOD BUCKS, |
| | PLEASE NOTE THE BUILDING CLASSIFICATION TYPE II-B |
| | SECTION 603.1 (1) FIRE RETARDANT TREATED WOOD CAN BE |
| | USED IN NON-BEARING PARTITIONS, PLEASE CORRECT WOOD |
| | BUCKS TO FIRE RETARDANT TREATED WOOD. |
| | |
| | 7) SHEET A-6 PARTITION GENERAL NOTE (6) INDICATES THE |
| | USE OF WATER RESISTANT GYPSUM BOARD ALL WET AREAS, |
| | PLEASE SEE 1210.2 FOR WALLS WITHIN 2?-0? OF WATER |
| | CLOSETS, URINALS SHALL HAVE A SMOOTH, HARD, |
| | NONABSORBENT SURFACE TO A HEIGHT OF 4?-0?. |
| | |
| | 8)NOTE THE MEP SHEETS THE ENGINEERING FIRM IS MISSING |
| | THEIR CERTIFICATE OF AUTHORIZATION. FLORIDA S. S. |
| | 471.023 CERTIFICATE OF AUTHORIZATION.THE TITLE BLOCK |
| | FOR ANY SHEET BEARING THE NAME OF AN ENGINEER |
| | PRACTICING UNDER A FICTITIOUS NAME, A |
| | CORPORATION, OR A PARTNERSHIP, OFFERING ENGINEERING |
| | SERVICES, SHALL INCLUDE THE CERTIFICATE OF |
| | AUTHORIZATION NUMBER. ADD THE NUMBER TO EACH SHEET. |
| | THIS MAY BE ADDED BY HAND. |
| | |
| | 9) CODE DATA COVER SHEET INDICATES AN OCCUPANT LOAD OF |
| | 124 REQUIRING 2 EXITS ASA STATED IN THE CODE ANALYSIS, |
| | PLEASE LOOK AT SHEET A-3 INDICATING AT THE REAR OF THE |
| | SHOW ROOM AN EXIT LIGHT FOR THE 2ND EXIT.PLEASE |
| | CORRECT NOTE ON SHEET A-1 REAR SET OF DOORS REMOVE |
| | ENTRY /EXIT HARDWARE AND LOCK SHUT!!!!!!! TABLE 1014.1 |
| | MERCANTILE OCCUPANT LOADS >50 REQUIRE 2 MEANS OF |
| | EGRESS. |
| | |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC |
| | |