| Date |
Text |
| 2008-08-04 16:32:18 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & |
| | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM |
| | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA |
| | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES |
| | (F.S.). |
| | |
| | *** DENIED *** |
| | THE FOLLOWING NOTES ARE FROM THE LAST REVIEW 2-7-08 |
| | THAT WERE NOT CORRECTED. |
| | |
| | 1) THE MAIN HOUSE AND THE GUEST HOUSE CAN NOT BE ON THE |
| | SAME ENERGY CALCULATION. PLEASE SUBMIT SEPARATE ENERGY |
| | CALCULATIONS FOR EACH BUILDING, SEE 2004 FBC |
| | 13-101.2.5.1. (THE OLD ENERGY CALCULATIONS WERE |
| | RESUBMITTED NOT REVISED ONES). |
| | |
| | 2) PLEASE HAVE THE REVISED ENERGY CALCULATIONS SIGNED |
| | BY OWNER/AGENT ALSO, SEE 2004 FBC 13-600.3.ABC.2. (SEE |
| | RESPONSE ABOVE #1). |
| | |
| | 3) ENERGY CALCULATIONS LINE 8B DOES NOT SHOW THE RAISED |
| | WOOD FLOOR OR INSULATION, SEE 2004 FBC 13-605.2.A.1.1 |
| | AND 13-605.1.C.2. PLEASE CORRECT ALSO THE PLANS IF |
| | NEEDED. (SEE RESPONSE ABOVE #1). |
| | |
| | 4) SHOW AN A/C EQUIPMENT SCHEDULE WITH ALL THE |
| | PERTINENT INFORMATION ON THE MECHANICAL PLAN, SEE 2004 |
| | WPB AMEND. 106.3.5.4 (10). (NO MECHANICAL PLANS WERE |
| | SUBMITTED FOR REVIEW). |
| | |
| | 5) SHOW ALL THE BATHROOM EXHAUST FANS ON THE MECHANICAL |
| | PLAN AS THEY ARE ON THE ELECTRICAL PLAN, SEE 2004 FBC/R |
| | R303.3 EXCEPT. (SEE RESPONSE ABOVE #4). |
| | |
| | 6) SHOW THE LOCATION OF THE GUEST HOUSE A/C CONDENSER |
| | UNIT ON THE MECHANICAL AND ELECTRICAL PLANS, SEE 2004 |
| | FBC/R M1307. (SEE RESPONSE ABOVE #4). |
| | |
| | 7) A/C SYSTEM 2 COOLING LOAD CALCULATIONS ARE CALLING |
| | FOR 23,601 TOTAL COOLING BTU'S. A 3 TON A/C SYSTEM AT |
| | 34,200 TOTAL COOLING BTU'S WOULD BE TO LARGE AS YOU CAN |
| | ONLY GO 15% OVER THE COOLING LOAD CALCULATION, SEE 2004 |
| | FBC 13-607.1.ABC.1.1. PLEASE CORRECT. (REVISED COOLING |
| | LOAD CALCULATIONS WERE SUBMITTED BUT NO MECHANICAL |
| | PLANS WERE SUBMITTED). |
| | |
| | 8) A/C SYSTEM 3 COOLING LOAD CALCULATIONS ARE CALLING |
| | FOR 23,046 TOTAL COOLING BTU'S. A 3 TON A/C SYSTEM AT |
| | 34,200 TOTAL COOLING BTU'S WOULD BE TO LARGE AS YOU CAN |
| | ONLY GO 15% OVER THE COOLING LOAD CALCULATION, SEE 2004 |
| | FBC 13-607.1.ABC.1.1. PLEASE CORRECT. (SEE RESPONSE |
| | ABOVE #7). |
| | |
| | 9) ELECTRICAL PLAN E-2 IS SHOWING A GAS INSTA-HOT WATER |
| | HEATER IN THE GARAGE OF THE GUEST HOUSE, THIS MAY BE A |
| | CONFINED SPACE. PLEASE SUBMIT COMBUSTION AIR |
| | CALCULATIONS, SEE 2004 FBC/R G2407.5. (THE GAS |
| | APPLIANCE MAY BE INSTALLED UNDER A SEPARATE PERMIT BUT |
| | THE SPACE THE GAS APPLIANCE IS BEING INSTALLED IN IS |
| | PART OF THIS PERMIT, PLEASE COMPLY). |
| | |
| | 10) PLEASE SUBMIT MANUFACTURER'S SPECIFICATION'S FOR |
| | THE GAS INSTA-HOT WATER HEATER AND GAS WATER HEATER |
| | BEING INSTALLED IN MAIN HOUSE, PER 2004 FBC/R G2407.1. |
| | (SEE RESPONSE ABOVE #9). |
| | |
| | 11) NEW NOTE: PLANS SHOW A GAS WATER HEATER BEING |
| | INSTALLED IN A CLOSET OF THE MAIN HOUSE FIRST FLOOR. |
| | THIS MAY BE A CONFINED SPACE, PLEASE SUBMIT COMBUSTION |
| | AIR CALCULATIONS, PER 2004 FBC/R G2407.5. |
| | |
| | 12) NOTICE: SEE ATTACHED NOTICE FS 553.80 (2) (B) |
| | REGARDING FOUR TIMES THE FEE. |
| | |
| | *** 2004 FBC/R G2407.1 (304.1) GENERAL. |
| | AIR FOR COMBUSTION, VENTILATION AND DILUTION OF FLUE |
| | GASES FOR GAS UTILIZATION EQUIPMENT INSTALLED IN |
| | BUILDINGS SHALL BE PROVIDED BY APPLICATION OF ONE OF |
| | THE METHODS PRESCRIBED IN SECTIONS G2407.5 THROUGH |
| | G2407.9 . WHERE THE REQUIREMENTS OF SECTION G2407.5 ARE |
| | NOT MET, OUTDOOR AIR SHALL BE INTRODUCED IN ACCORDANCE |
| | WITH ONE OF THE METHODS PRESCRIBED IN SECTIONS G2407.6 |
| | THROUGH G2407.9 . DIRECT-VENT APPLIANCES, GAS |
| | APPLIANCES OF OTHER THAN NATURAL DRAFT DESIGN AND |
| | VENTED GAS APPLIANCES OTHER THAN CATEGORY I SHALL BE |
| | PROVIDED WITH COMBUSTION, VENTILATION AND DILUTION AIR |
| | IN ACCORDANCE WITH THE EQUIPMENT MANUFACTURER?S |
| | INSTRUCTIONS. |
| | |
| | MECHANICAL PLAN REVIEW BY; |
| | TOM GORDON (561) 805-6729 |
| | E-MAIL; [email protected] |