Plan Review Notes
Plan Review Notes For Permit 08010603
Permit Number 08010603
Review Stop B
Sequence Number 1
Notes
Date Text
2008-01-29 16:50:54 
  
 DENIED
  
 1)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING
 MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF
 ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND
 STATE ON THE DRAWINGS. *******PLEASE NOTE FOR EXAMPLE
 THAT IF AN ALTERATION LEVEL 1 IS CHOSEN AND ANY WORK
 OUTSIDE OF REMOVAL AND REPLACEMENT OF MATERIALS AND/OR
 COMPONENTS THAT SERVE THE SAME PURPOSE WOULD CONSTITUTE
 AND DIFFERENT LEVEL OF ALTERATION AND CAUSE PERMIT
 CANCELLATION*******
  
 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
 *******IF CORRECT VALUE IS NOT PROVIDED THESE GUIDES
 WILL BE USED TO ACERTAIN VALUE AND PERMIT FEES WILL BE
 ADJUSTED*******
  
 3)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF
 EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE
 SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES.
 ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG
  
 4)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVALSHEETS WHEN AVAILABLE. THEY CAN
 BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG.WHEN
 AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE
 DENIED
  
 5)NO PRODUCT APPROVALS WERE SUBMITTED FOR IMPACT
 PROTECTION DEVICES, MULLION AND SLIDING GLASS DOORS,
 ALSO A NAMI CERTIFICATION WAS SUBMITTED FOR JELD-WEN
 GLAZED DOOR BUT NO LOCATION SHOWN ON THE DRAWING OR
 PRODUCT APPROVAL WAS SUBMITTED.
  
 6)SHUTTER PERMIT APPLICATIONS REQUIRE A KEY PLAN
 (WITH EGRESS SHOWN), SHUTTER SCHEDULE AND THE PRODUCT
 APPROVALS. APPROVAL DRAWINGS CAN BE MARKED FOR MOUNTING
 METHOD AND CONNECTION TYPE AND THE SCHEDULE FILLED OUT
 WITH ALL PERTINENT INFORMATION SPECIFIC TO THE SITE
 (TYPE OF CONSTRUCTION, MOUNTING CONNECTION METHOD,
 ANCHOR TYPE, SHUTTER SPAN (VERTICAL OR HORIZONTAL),
 ETC.) PLEASE SEE THE ATTACHED MEMO AND SCHEDULE.
  
 7)CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION,NATURE, AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE PER 106.1.1
 FBC*.
 *******REMODEL PERMITS THAT ARE FOR THE REPLACEMENT OF
 EXISTING DOORS OR WINDOWS SHALL INCLUDE A PLAN VIEW
 LAYOUT SHOWING THE LOCATION OF ALL OPENINGS AND THE
 SIZES, TYPE AND LOCATION OF DOOR AND WINDOWS THAT WILL
 BE REPLACED AND ANY CONFIGURATION, SUCH AS 2 OR MORE
 UNITS ATTACHED TOGETHER WITH MULLIONS********
  
 8)PROVIDE A COMPLETE SCOPE OF WORK DETAILING ALL WORK
 TO BE PERFORMED AS INSPECTORS FINDING WORK OTHER THAN
 THAT STATED IN THE SCOPE MAY CAUSE FAILED INSPECTIONS
 AND FURTHER DELAYS WITH REVISIONS TO BE SUBMITTED TO
 BLDG. DEPT.
  
 9)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER
 AND OWNER/AGENT PRIOR TO SUBMITTAL
  
 10)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER
 R313.1.1 FBC RES.
  
 11)SUBMIT A COPY OF THE RECORDED NOTICE OF
 COMMENCEMENT TO THE CONSTRUCTION SERVICES DEPARTMENT.
  