| Date |
Text |
| 2008-01-27 21:03:47 | BUILDING PLAN REVIEW |
| | PERMIT: 08010437 |
| | ADD: 1041 45TH ST |
| | CONT: ** PLAN REVIEW** |
| | TEL: (561)###-#### |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1STREVIEW"PLAN REVIEW" |
| | ACTION: DENIED |
| | |
| | 1A)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS, |
| | REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR |
| | REVIEW FOR PERMIT. |
| | IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF |
| | YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A |
| | THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID |
| | DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* |
| | /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH |
| | ADMINISTRATIVE CODE. |
| | |
| | 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 |
| | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN |
| | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF |
| | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY |
| | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE |
| | SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS |
| | A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS |
| | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE |
| | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT |
| | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| | DETERMINED BY THE BUILDING OFFICIAL. |
| | |
| | 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE |
| | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT |
| | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) |
| | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC |
| | BUILDING WITH THE2007 SUPPLEMENTS. |
| | |
| | 2)) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION |
| | THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE |
| | OF OCCUPANCY: |
| | A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS |
| | DESIGNED.UPDATE THE CODE COMPLIANCE TO INCLUDE THE 2007 |
| | SUPPLEMENTS. |
| | B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE |
| | PROVISIONS OF CHAPTER 3. COMPLIED. |
| | C) THE TYPE OF CONSTRUCTION AS DEFINEDIN CHAPTER 6, |
| | TABLE 601. TAGLE 601 CONSTRUCTION TYPE IIIA OR IIIB? D) |
| | THE OCCUPANT LOAD, SEE 1004.COMPLIED. |
| | E) IF AN AUTOMATIC SPRINKLER SYSTEM ISPROVIDED? F) |
| | WHETHER THE SPRINKLER SYSTEM IS REQUIRED? (AREA |
| | INCREASES) |
| | G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE |
| | BUILDING PERMIT |
| | .H) NUMBER OF FLOORS |
| | THE ABOVE MENTIONED REQUIREMENTS ARE NEEDED TO DO AN |
| | ACCURATE REVIEW UNDER THE CURRENT CODES. |
| | |
| | 3) THE TECHNICAL SPECIFICATIONS INDICATE THE PRESENCE |
| | OF ASBESTOS. PLEASE SEE WPB ADMINISTRATIVE CODE |
| | 105.3.6* ,553.79 FL SS & 455.302 FL SSFOR ASBESTOS |
| | REMOVAL. THIS ABATEMENTOF ASBESTOS MUST BE BY STATE |
| | LAW MUST BE ACCOMPLISHED BYLICENSED CONTRACTORS. |
| | BFORE ABATEMENT OF ASBESTOS |
| | REQUIREMENTS INCLUDE - ASBESTOS SURVEY AND SUBMISSION |
| | OF WRITTEN NOTIFICATION TO THE FLORIDA DEPARTMENT OF |
| | ENVIROMENTAL PROTECTION PRIOR TO MOST RENOVATION |
| | ACTIVITIES IN REGULATED STRUCTURES WHERE ASBESTOS IS |
| | DISTURBED OR REMOVED. FOR FURTHER INFORMATION IN PALM |
| | BEACH COUNTY, CONTACT THE DIVISION OF ENVIROMENTAL |
| | HEALTH & ENGINEERING HRS/ PALM BEACH COUNTY HEALTH |
| | UNIT. |
| | HAS THE WRITTEN PERMISSION FOR REMOVAL OF ASBESTOS BEEN |
| | OBTAINED FOR THE PB COUNTY HEALTH DEPARTMENT? |
| | |
| | 4) ON VARIOUS SHEETS WHERE THE DUCTS CROSS SMOKE |
| | BARRIERS FROM ONE CHAMBER TO ANOTHER THE DUCTS ARE |
| | MISSING SMOKE DAMPERS. PLEASE ILLUSTRATE CODE |
| | COMPLIANCE WITH 716.1.1 AND OR 712.3. AND 712.3.4. |
| | |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |