2008-01-28 10:19:36****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.PLEASE CLARIFY SCOPE OF WORK ON SHEET A1.THERE
 ARE TWO SECTIONS OF WALL; ARE YOU DOING BOTH UNDER THE
 SCOPE OF THIS PERMIT?
  
 2.REGARDING THE 8 1/2 X 11 DETAIL SHEET, ALL
 INFORMATION REQUIRED BY FAC61G16-23.002, 003 IS TO BE
 ON EACH SHEET.NOTE THAT THE SPECIFICS AS TO WHO
 SIGNED AND SEALED THE DOCUMENT IS LACKING.
  
 3.PLEASE REVISE EITHER THE SITE PLAN, A1, OR THE
 DETAIL SHEET, A1.3, TO SHOW THE FOOTING IN RELATION TO
 THE LOT LINE.YOU CANNOT ENCROACH THE PROPERTY LINE.
 AS DRAWN, THE COLUMN SITS ON THE PROPERY LINE ON THE
 EAST SIDE, AND VERY CLOSE TO THE PROPERTY LINE ON THE
 NORTH SIDE, WHICH WOULD REQUIRE THE FOOTING TO SIT ON
 CITY AND NEIGHBORING PROPERTY.THIS COMMENT APPLIES TO
 THE OTHER 3 COLUMNS SHOWN ON THE PLAN AS WELL.
  
 4.A1 STATES THAT THE COLUMNS ARE 12X12, A1.3 SHOWS A
 1'4" COLUMN.PLEASE RESOLVE CONFLICTING DETAILS.
  
  