| 2008-01-24 12:34:46 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.SEE SHEET 3 OF THE PRODUCT APPROVAL, AND SEE | | | OPENING 6 ON THE INSTALLATION SCHEDULE.THIS SPAN OF | | | 86" (ANCHOR TO ANCHOR) REQUIRES US OF THE COLUMN FOR | | | "SPAN UP TO 7'6"", 120 ROW (AS YOUR DESIGN PRESSURE OF | | | 67.3 IS GREATER THAN 65PSF), REQUIRES ANCHOR SPACING OF | | | 3.7", NOT 5" AS SPECIFIED ON THE INSTALLATION SCHEDULE. | | | PLEASE CHECK ALL OPENINGS AS THIS COMMENT MAY APPLY TO | | | OTHER OPENINGS.PLEASE REVISE THE INSTALLATION | | | SCHEDULE. | | | |
|