2010-05-20 13:21:24*****PROVISO******
 IF SEPARATE FIXTURE LABELED LAV IS ACTUALLY AN EMPLOYEE
 LOUNGE SINK,
 THEN THE SINK SHALL COMPLY WITH 11-4.24 ACCESSIBILITY
 CODE
 SINKS SHALL BE MOUNTED WITH THE COUNTER OR RIM NO
 HIGHER THAN 34 INCHES (865 MM) ABOVE THE FINISH FLOOR.
 KNEE CLEARANCE THAT IS AT LEAST 27 INCHES (685 MM)
 HIGH, 30 INCHES (760 MM) WIDE, AND 19 INCHES (485 MM)
 DEEP SHALL BE PROVIDED UNDERNEATH SINKS.
  