2008-02-15 11:19:30*** DENIED3RD REVIEW***
  
 ** PLEASE SEE SOME ITEMS WHICH ARE THE SAME FROM THE
 TWO PREVIOUS REVIEWS ARE STILL IN NEED OF ADDRESSING.
  
 1) NOTE: PLEASE SEE THE TWO PREVIOUS REVIEWS STATED NEC
 230.72 FOR GROUPING OF MAINS AND TO SHOW THE LOCATION
 OF ALL EQUIPMENT ON PLANS.
 PLEASE SEE THE RISER AND PLANS STILL SHOW THE NEW MCB
 PANEL FOR UNIT 101 IN THE UNIT WHICH DOES NOT GROUP
 MAINS AS REQUIRED PER CODE.
 PLEASE RELOCATE AND COMPLETE RISER WITH ALL
 INFORMATION.
 240.24, 110.26, 230.72 ETC
 ** KEEP IN MIND AS ADDING A NEW MAIN OUTSIDE GROUPED
 WITH OTHER MAINS WILL BE REQUIRED, PLEASE BE SURE TO
 INCLUDE ALL CODE COMPLIANCE INFORMATION FOR NEW
 DISCONNECT INCLUDING AN EQUIPMENT GROUNDING CONDUCTOR
 FROM NEW MAIN TO PANEL INSIDE.
  
 2) NOTE: PLEASE SEE PREVIOUS NOTES REQUESTED TO SHOW
 THE LOCATION OF THE REQUIRED SIGN CIRCUIT. THE PANEL
 SCHEDULE SHOWS THE REQUIRED CIRCUIT HOWEVER THE
 ELECTRICAL PLANS STILL DO NOT SHOW THIS LOCATION.
 PLEASE SEE 600.5
  
 3) NOTE: PLEASE SEE ATTACHED PRINT OUT OF FLORIDA
 STATUTES 553.80(2)(B) WITH RESPECT TO REPEAT COMMENTS
 FOR CODE COMPLIANCE.
 THE SAME CODE SECTIONS FOR GROUPING OF MAINS HAVE BEEN
 CITED THREE TIMES. THE FEE AS REQUIRED BY STATUE IS
 ASSESSED. THIS IS A STATE STATUE AND NOT A LOCAL
 ADMINISTRATIVE ASSESSMENT.
 PLEASE SEE THE FEE OF $ 379.20 IS REQUIRED TO BE PAID
 BEFORE RESUBMISSION OF PLANS.
  
 ** IF THERE ARE QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]