| Date |
Text |
| 2008-09-09 11:36:51 | BUILDING PLAN REVIEW |
| | PERMIT: 08010249 |
| | ADD: 295 LAKEVIEW AVE. |
| | CONT: KAST CONSTRUCTION |
| | TEL: (561)718-6141 |
| | E-MAIL: [email protected] |
| | |
| | ARCH: PFVS/ GREGORY R PORTMAN |
| | TEL: (404)503- 5000 |
| | |
| | STRUC: OMNJ/ THOMAS M BOG ACKI |
| | TEL: (561)835-9994 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | SUBMITTAL REVIEW |
| | ACTION: DENIED |
| | |
| | LOUVERS & MULLIONS: |
| | |
| | 1) RULE 9B-72 REQUIRES PRODUCT APPROVALS THAT ARE |
| | LISTED WITH EITHER THE FLORIDA STATE WEBSITE OR ANOTHER |
| | APPROVED AGENCY SUCH AS UL OR MIAMI-DADE WITH THIRD |
| | PARTY QUALITY ASSURANCE PROGRAM IN EFFECTTHAT IS |
| | REGISTERED WITH THE STATE. |
| | |
| | 2) 1609.1.4(5) LOUVERS. LOUVERS PROTECTING INTAKE AND |
| | EXHAUST VENTILATION DUCTS NOT ASSUMED TO BE OPEN THAT |
| | ARE LOCATED WITHIN 30 FEET (9144 MM) OF GRADE SHALL |
| | MEET REQUIREMENTS OF THE LARGE MISSILE TEST. |
| | IMPACT-RESISTANT COVERINGS SHALL BE TESTED AT 1.5 TIMES |
| | THE DESIGN PRESSURE (POSITIVE OR NEGATIVE) EXPRESSED IN |
| | POUNDS PER SQUARE FEET AS DETERMINED BY THE FLORIDA |
| | BUILDING CODE, BUILDING SECTION 1609 FOR WHICH THE |
| | SPECIMEN IS TO BE TESTED. |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |