Plan Review Notes
Plan Review Notes For Permit 08010237
Permit Number 08010237
Review Stop B
Sequence Number 2
Notes
Date Text
2008-06-03 16:12:35 
  
 DENIED
  
 THE FOLLOWING COMMENTS WERE NOT ADDRESSED FROM 1ST
 REVIEW:
  
 10)NO PRODUCT APPROVALS WERE SUBMITTED FOR CONNECTORS
 AND STRAPS. IN LUE OF PRODUCT APPROVALS
 STRAPS/CONNECTORS MAY BE LISTED IN A SCHEDULE ON THE
 DRAWINGS COMPLETE WITH THE STATEWIDE PRODUCT APPROVAL
 NUMBERS OR SUBMIT SIMPSON TIE'S COMPLETE FLORIDA INDEX
 WITH CONNECTORS TO BE USED HIGHLIGHTED.
  
 16)ADDITIONS ARE TREATED AS NEW CONSTRUCTION, PROVIDE
 AT MINIMUM 1 ACCESSIBLE BATHROOM PER R322.1.1 FBC 29"
 CLEAR WITH DOOR OPEN 90 DEGREES.
 **********DOOR NOT SHOWN AS 32" PER ARCHITECTS RESPONSE
 LETTER*********
  
 18)PROVIDE DETAIL OF FOUNDATION AND COLUMN TIE INS
 INTO EXISTING FOUNDATIONS AND WALLS *********SUPPORT IS
 OK, COMMENT REFERS TO CONNECTION OF NEW ADDITION TO
 EXISTING BUILDING, IS 8" X 12" COLUMN OR NEW FOUNDATION
 AT SITTING AREA FREE STANDING OR ARE THEY DOWELED INTO
 EXISTING WALL? IS THERE AN EXPANSION JOINT AT THESE
 LOCATIONS? DOES ROOF TIE IN WITH CRICKET TO EXISTING
 SHED ROOF ?
  
 NEW COMMENTS
  
 1)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561) 233-5025 FOR MORE
 INFORMATION
  
 2)ENERGY CALC'S FOR GUEST HOUSE WERE NOT SIGNED BUY
 OWNER/AGENT
  
 3)PER LIMITATION #7 OF THE MODIFIED BITUMEN ROOFING
 PRODUCT APPROVAL CALCULATIONS FOR ENHANCED FASTENING IS
 REQUIRED FOR THE PERIMETER AND CORNER ZONES TO BE
 PREPARED, SIGNED AND SEALED BY A REGISTERED ENGINEER,
 ARCHITECT OR ROOFING CONSULTANT.
  
 4)CLARIFY WERE THE SINGLE PLY ROOFING SYSTEM WILL BE
 USED
  
 5)PROVIDE PRODUCT THAT WILL BE USED FOR RIDGE VENTING
 OF ACFOAM CROSSVENT PRODUCT AND STAND 'N' SEAM ALUMINUM
 ROOFING
  
 6)NO PRODUCT APPROVALS WERE SUBMITTED FOR MULLIONS
 BETWEEN FRENCH DOORS/ SIDE LITESAND FRENCH DOORS /
 TRANSOMS
  
 NOTE FEES HAVE BEEN ADJUSTED FOR BOTTOM OF ACCESSORY
 STRUCTURE PER APPROVAL OF ROBERT BROWN 100 SQ FT AS
 UTILITY (ELEVATOR AND ELEVATOR MACHINE ROOM) THE
 REMAINDER DISCOUNTED $10.33 PER SQ FT FROM UTILITY
 RATE. THE NEW FEE TOTAL FOR STRUCTURES AND RADON FEES
 IS $595.98
  