Plan Review Notes
Plan Review Notes For Permit 08010228
Permit Number 08010228
Review Stop B
Sequence Number 1
Notes
Date Text
2008-01-22 10:53:572004 FBC W/2007 REVISIONS
 ADDITION OF A FRONT ENTRY
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) FBC 1603.1.4WIND DESIGN DATA.THE
 PLANS SHALL STATE THE BASIC WIND SPEED,
 WIND IMPORTANCE FACTOR, WIND EXPOSURE
 CATEGORY, INTERNAL PRESSURE COEFFICIENT,
 AND EXTERIOR COMPONENT AND CLADDING
 DESIGN WIND PRESSURES.ADD THIS
 INFORMATION TO THE PLANS.
  
 4) SUBMIT 2 SIGNED AND SEALED SOIL REPORTS. THE
 SUBSURFACE SOIL REPORTS ARE REQUIRED TO HAVE THE
 EMBOSSED SEAL, ORIGINAL SIGNATURE AND DATE OF THE SOIL
 ENGINEER. SEE FS 471 AND FAC 61G15-23.002.
  
 5) THE ROOF SHEATHING IS REQUIRED TO BE ATTACHED WITH
 8D RING SHANK NAILS. ROOF SHEATHING IS REQUIRED TO BE
 IN ACCORDANCE WITH SECTION R803.2.3.1 OF 2006 REVISIONS
 TO 2004 FBC RESIDENTIAL CODE. WOOD STRUCTURAL PANEL
 SHEATHING SHALL BE FASTENED TO ROOF FRAMING WITH 8D
 RING-SHANK NAILS AT 6 INCHES ON CENTER AT EDGES AND 6
 INCHES ON CENTER AT INTERMEDIATE FRAMING. SPACING OF
 RING-SHANK FASTENERS SHALL BE 4 INCHES ON CENTER IN
 NAILING ZONE 3 FOR 130 MPH OR GREATER DESIGN WIND
 SPEEDS IN ACCORDANCE WITH FIGURE R803.2.3.1. REVISE
 NOTES ON DRAWING 5.
  
 6) THE NUMBER OF FASTENERS SPECIFIED FOR THE SIMPSON
 FGTR SHOULD BE 36- SDS 1/4" X 3". THE NUMBER OF
 FASTENERS FOR THE LSSU28 SHOULD BE 10-10D AT THE FACE
 AND 5- 10D X 1-1/2" AT THE JOIST. PLEASE CORRECT
 SCHEDULE ON DRAWING 5.
  
 7) SHOW COMPLIANCE WITH R802.1.6 WOOD TRUSSES.
 R802.1.6.1 TRUSS DESIGN DRAWINGS.
 TRUSS DESIGN DRAWINGS, PREPARED IN CONFORMANCE WITH
 SECTION R802.1.6.1 , SHALL BE PROVIDED TO THE BUILDING
 OFFICIAL AND APPROVED PRIOR TO INSTALLATION. TRUSS
 DESIGN DRAWINGS SHALL INCLUDE, AT A MINIMUM, THE
 INFORMATION SPECIFIED BELOW. TRUSS DESIGN DRAWING SHALL
 BE PROVIDED WITH THE SHIPMENT OF TRUSSES DELIVERED TO
 THE JOBSITE.
 1.DESIGN WIND SPEED AND EXPOSURE CATEGORY.
 2.SLOPE OR DEPTH, SPAN AND SPACING.
 3.LOCATION OF ALL JOINTS.
 4.REQUIRED BEARING WIDTHS.
 5.DESIGN LOADS AS APPLICABLE.
 5.1.TOP CHORD LIVE LOAD.
 5.2.TOP CHORD DEAD LOAD.
 5.3.BOTTOM CHORD LIVE LOAD.
 5.4.BOTTOM CHORD DEAD LOAD.
 5.5.CONCENTRATED LOADS AND THEIR POINTS OF
 APPLICATION.
 5.6.CONTROLLING WIND AND EARTHQUAKE LOADS.
 6.ADJUSTMENTS TO LUMBER AND JOINT CONNECTOR DESIGN
 VALUES FOR CONDITIONS OF USE.
 7.EACH REACTION FORCE AND DIRECTION.
 8.JOINT CONNECTOR TYPE AND DESCRIPTION (E.G.,
 SIZE, THICKNESS OR GAUGE) AND THE DIMENSIONED LOCATION
 OF EACH JOINT CONNECTOR EXCEPT WHERE SYMMETRICALLY
 LOCATED RELATIVE TO THE JOINT INTERFACE.
 9.LUMBER SIZE, SPECIES AND GRADE FOR EACH MEMBER.
  
 10.CONNECTION REQUIREMENTS FOR:
 10.1.TRUSS TO TRUSS GIRDER.
 10.2.TRUSS PLY TO PLY.
 10.3.FIELD SPLICES.
 11.CALCULATED DEFLECTION RATIO AND/OR MAXIMUM
 DESCRIPTION FOR LIVE AND TOTAL LOAD.
 12.MAXIMUM AXIAL COMPRESSION FORCES IN THE TRUSS
 MEMBERS TO ENABLE THE BUILDING DESIGNER TO DESIGN THE
 SIZE, CONNECTIONS AND ANCHORAGE OF THE PERMANENT
 CONTINUOUS LATERAL BRACING. FORCES SHALL BE SHOWN ON
 THE TRUSS DESIGN DRAWING OR ON SUPPLEMENTAL DOCUMENTS.
  
 13.REQUIRED PERMANENT TRUSS MEMBER BRACING
 LOCATION.
  
 8) R802.1.6.2 DESIGN.
 WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH
 ACCEPTED ENGINEERING PRACTICE. THE DESIGN AND
 MANUFACTURE OF METAL PLATE CONNECTED WOOD TRUSSES SHALL
 COMPLY WITH ANSI/TPI 1. THE TRUSS DESIGN DRAWINGS SHALL
 BE PREPARED BY A REGISTERED PROFESSIONAL WHERE REQUIRED
 BY THE STATUTES OF THE JURISDICTION IN WHICH THE
 PROJECT IS TO BE CONSTRUCTED IN ACCORDANCE WITH SECTION
 R106.1 .
  
 9) SUBMIT PRODUCT APPROVALS FOR THE TILE ROOF
 UNDERLAYMENT THAT WILL BE USED. SEE RAS 120 AND FAC
 RULE 9B-72.
  
 10) REVISE UNDERLAYMENT NOTES ON DRAWING 5 TO COMPLY
 WITH RAS 120 AND CORRESPOND TO THE PRODUCT APPROVAL FOR
 THE TILE UNDERLAYMENT. FBC 106.1.1.
  
 - ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]