2008-01-11 13:58:502004 FBC W/2007 REVISIONS
 CONVERT GARAGE TO LIVING SPACE
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) SPECIFY THE FLOOR LIVE LOAD ON THE PLANS. 2004 FBC
 R501.2 REQUIREMENTS.
 FLOOR CONSTRUCTION SHALL BE CAPABLE OF ACCOMMODATING
 ALL LOADS ACCORDING TO SECTION R301 AND OF TRANSMITTING
 THE RESULTING LOADS TO THE SUPPORTING STRUCTURAL
 ELEMENTS. SEE TABLE R301.5.
  
 4) SPECIFY THE HANGERS THAT WILL BE USED TO SUPPORT THE
 FLOOR JOIST. FBC 106.1.1* CITY AMENDMENTS.
  
 5) A 2X6 LEDGER IS SPECIFIED TO PROVIDE ATTACHMENT FOR
 THE 2 X12 FLOOR JOISTS. PLEASE EVALUATE THAT THESE WILL
 PROVIDE ADEQUATE SURFACE AREA FOR FASTENING OF THE
 JOIST HANGERS.
  
 6) SPECIFY THE REQUIRED EMBED DEPTH OF THE 3/8" TAP
 CONS THAT WILL BE USED TO ATTACH THE 2 X 6 LEDGER TO
 THE CBS WALLS. PROVIDE A SIGNED AND SEALED EVALUATION
 WITH CALCULATIONS OF THE ATTACHMENT OF THE 2 X 6 LEDGER
 TO CONCRETE BLOCK WITH 3/8" TAPCONS AT 24" O.C. AND
 THEIR CAPACITY TO SUPPORT ALL IMPOSED LOADS.FBC
 106.1.1* CITY AMENDMENTS.
  
 7) SPECIFY THE CEILING HEIGHT ON THE PLANS. SHOW
 COMPLIANCE WITHR305.1 MINIMUM HEIGHT .
 HABITABLE ROOMS, HALLWAYS, CORRIDORS, BATHROOMS, TOILET
 ROOMS, LAUNDRY ROOMS AND BASEMENTS SHALL HAVE A CEILING
 HEIGHT OF NOT LESS THAN 7 FEET (2134 MM). THE REQUIRED
 HEIGHT SHALL BE MEASURED FROM THE FINISH FLOOR TO THE
 LOWEST PROJECTION FROM THE CEILING .
  
 8)SUBMIT TWO COPIES OF ENERGY CALCUALTIONS SIGNED AND
 DATED BY THE PREPARER AND THE OWNER/AGENT AS REQUIRED
 BY FBC CHAPTER 13.
  
 10)SUBMIT 2 COPIES OF PRODUCT APPROVALS FOR THE NEW
 IN-SWING EXTERIOR DOOR. FAC RULE 9B-72.
  
 11)FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS.
 THOSE PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 - ROBERT MCDOUGAL